protected  must  be  at  least  30  cm  on  the  side  and  30  cm  on  the  back  of  the  furnace.  Flammable  items 
need to be at a distance of at least 80 cm from the opening of the furnace. 
You  should  leave  sufficient  space  between  the  furnace  and  the  flammable  objects  (wood  paneling, 
furniture, curtains, etc.). 
Installation of objects above the furnace is not allowed if you use the furnace top surface.  
When  installing  the  drain  pipes  for  used  air,  you  should  leave  a  gap  of  at  least  40  cm  away  from  the 
flammable materials. 
Before connecting the furnace to the chimney,  you should consult a competent local chimney sweeping 
institution.  Connecting  the  chimney  to  the  furnace  is  done  through  the  connecting  elements  in 
SRPS.M.R4.031  (DIN 1298 or DIN EN 1856-2). Make sure that the connecting parts for the chimney do 
not enter the waste gases drain intersection, and that they are properly sealed

 

5. Air Regulation 

Air regulation is done on the front side of the furnace under the cover. 
Air regulators on the front side of the furnace enable the ignition and fuel combustion. 
Make sure that the ash tray is not filled up. You should empty it regularly as to enable the unobstructed 
airflow. 
Due to the poor supply of oxygen, there are large emissions of harmful substances, which can lead to 
blocking the chimney. 

 

5.1 Primary Air 
 

Reliable fuel combustion is determined based on the primary   
combustion air. 
This air is adjusted by regulating the primary air to the front side of 
the furnace under the cover. Air regulation is done on the front side 
of the furnace under the cover.   
 

Fig. 2                                   

Figure 2, position 7 shows the opening and the closing   

         

 

 

         

 

direction of the regulator. To fire the wood, the regulator 

                                            

needs to be opened as much as possible. 

NOTE: To avoid overheating of the furnace, the quantity of fuel must not exceed 2.0 kg of dry log wood or 
brown coal briquettes per hour, when the combustion air is properly adjusted.    

                 

5.2 Using the Handle on the Firebox Door 
                                                               

 

 

                                                                      As the handle on the firebox door  
                                                                      becomes extremely hot while the furnace is 
                                                                      in operation, opening and closing of the firebox door 
 

 

 

 

 

     is possible only by using a special key from the  

                                                                      attached furnace accessories (see Fig. 3). 

 
                                                                   
                                                                       
                                           Fig. 3 
 
 
 
 

 

Summary of Contents for ALPHA FURNACE 2014

Page 1: ...METALNA INDUSTRIJA AD RADNI KA 1 17 500 VRANJE SERBIA TEL 017 421 121 SOLID FUEL PROGRAMME ALPHA FURNACE 2014 INSTRUCTIONS FOR INSTALLATION ADJUSTMENT AND USE...

Page 2: ...ce is located then the combustion air fresh air needs to be brought in from the outside as necessary In this regard it is necessary to consult with a competent chimney organization before the furnace...

Page 3: ...sh tray volume 9 dm3 capacity to heat up the room 100 150m3 type of fuel timber lignite brown coal mass 110 kg regulated combustion with the option to adjust the required amounts of air using the air...

Page 4: ...g of the lateral right side combustion door is done using a special wrench by lifting the handle and placing the wrench cogwheel into the handle opening In the middle part of the furnace there are two...

Page 5: ...to the chimney make sure that flue pipe does not go deep into the chimney opening as this reduces the space for the smoke to come out Then preferably seal the joint flue pipe chimney Two furnaces mus...

Page 6: ...on the front side of the furnace enable the ignition and fuel combustion Make sure that the ash tray is not filled up You should empty it regularly as to enable the unobstructed airflow Due to the poo...

Page 7: ...rmed load new fuel through the fire opening and adjust the air regulator for primary air according to the type of fuel Never put new fuel onto the flame A certain amount of smoke is released when the...

Page 8: ...he entire furnace should be regularly checked by an expert The furnace flue and chimney must be cleaned regularly several times a year and at least once during the heating season Regular maintenance a...

Page 9: ...SERVES ALL RIGHTS TO CHANGES Within the warranty period the furnace will only function properly if used in accordance with the instructions for installation and use of the appliance The warranty shall...