1. INTRODUCTION
8
u
Advanced Power Protection Technology
The Alpha Nexsys uninterruptible power supplies (UPS) provides continu-
ous and conditioned AC power to equipment such as computers, telephone
key switches, and other ancillary phone equipment.
u
Advanced Communications
An RS–232 port allows remote supervision of the UPS.
u
Smart Charging
Alpha’s smart charge technology ensures the internal batteries are
consistently at peak performance level and automatically selects higher
charge current when an external battery pack is connected.
u
Tower Installation
The Nexsys UPS can be configured to stand on the floor next to the loads.
The external battery pack can be joined to the UPS.
u
Wall Mount Installation
The Nexsys UPS mounts easily on a wall adjacent to key systems. The
external battery pack can be wall mounted near the UPS.
u
Rack Mount Installation
The Nexsys UPS mounts easily in a standard equipment rack to provide
power to other modules in the rack. The external battery pack can also be
rack mounted.
u
Expandable Runtime Capabilities
Nexsys external battery packs can be daisy chained to increase backup
time to over 8 hours.
u
Power Boost
Power boost increases output voltage in brownout conditions.
u
Service Friendly
Battery servicing is quick and easy.
u
Generator Standby Mode
The UPS can run with a generator as a power source.
1.1
The Alpha Advantage
5. MAINTENANCE
53
5.4
Troubleshooting
Notice
The UPS generates, uses, and can radiate radio frequency energy if not
installed and used in accordance with the instructions contained in the manual.
The UPS has been tested and found to comply with the limits established for a
Class A computing device pursuant to Part 15 of FCC rules and the radio
interference regulations of DOC which are designed to provide reasonable
protection against such interference when this type of equipment is operated in
a commercial environment. If the UPS appears to cause interference to radio or
television reception, which can be determined by switching the unit off and on,
relocate the equipment and/or use an electrical circuit other than that used by
the UPS.
SYMPTOM
CAUSE
REMEDY
UPS does not turn on
when
On/Off switch
turned on.
Discharged batteries.
or
Faulty circuit.
Charge batteries.
Contact vendor.
On Line mode does not
come on.
No AC line power.
or
AC line voltage too high
or low.
or
On/Off switch turned off.
Wait for AC line power.
Check input circuit
breaker.
Wait for voltage to
stablilize.
Turn on
On/Off switch.
On Battery mode does
not come on during
power failure.
Low battery charge.
or
Faulty circuit.
Charge batteries.
Contact vendor.
Backup time is less than
rated or flashing
Low
Battery LED.
Battery is not fully
charged.
or
Charger failure.
or
Battery failure.
or
Faulty circuit.
Recharge batteries for
at least 4 hours, then
test the backup time
Contact vendor.
Clean and tighten
connections.
Check batteries and
replace if necessary.
Contact vendor.
Fault LED is on or
flashing.
Check fault codes.
Correct fault.
Contact vendor.