Chapter 4 Parameter Index
42
Function
code
Parameter name
Setting range
Factory
setting
Modify
flag
Modbus
address
Pb.03
Communication
timeout detection
time
0.0~100.0s
0: No timeout detection
Other: Timeout detection time
0.0s
○
0C03
Pb.04
Response delay
time
0~500ms 5ms
×
0C04
Pb.05
Communication
transmission
frequency
command unit
0: 0.01Hz
1: 0.1Hz
0 ×
0C05
Pb.06
Communication
data Eeprom save
options
0: Not save Eeprom directly
1: Save Eeprom directly
0 ×
0C06
Pb.07
CCF6
Troubleshooting
0: Resume without reporting
failure
1: Reported failure and shut
down automatically
0 ×
0C07
Pb.08 Reserve
Reserve
0
-
0C08
PC: Display Control
Function
code
Parameter name
Setting range
Factory
setting
Modify
flag
Modbus
address
PC.00
LCD Language
Selection
0: Chinese
1: English
0
○
0D00
PC.01
Output frequency
(Hz)
(Before
compensation)
0: Not displayed 1:
Displayed
1
○
0D01
PC.02
Output frequency
(Hz)
(Actual)
0: Not displayed 1:
Displayed
0
○
0D02
PC.03
Output current
(A)
0: Not displayed 1:
Displayed
1
○
0D03
PC.04
Set frequency
(Hz flicker)
0: Not displayed 1:
Displayed
1
○
0D04
PC.05 Reserve
-
-
*
0D05
PC.06~
PC.08
Set speed
(R / min blink)
0: Not displayed 1:
Displayed
0
○
0D06
PC.09
Output power
(kW)
0: Not displayed 1:
Displayed
0
○
0D09
PC.10
Output torque
(%)
0: Not displayed 1:
Displayed
0
○
0D0A
PC.11
Output voltage
(V)
0: Not displayed 1:
Displayed
1
○
0D0B
PC.12
Bus voltage (V)
0: Not displayed 1:
Displayed
0
○
0D0C