Chapter 5 Detailed Function Introductions
58
Orientation
timing
Orientation
curve
Determine the position of the spindle orientation
Spindle use encoder Z signal as the reference origin(0 pulse points)and display
position to the form of pulse
。
For example,a ring of 4096(4 times frequency)
:
1
360
0.088
4096
o
o
1
、
Lift the spindle orientation stop signal,so that the spindle is in free state
。
2
、
Manual rotation so that the spindle stop at the target location(if the spindle
encoder is used ,please forward rotation of the spindle in a circle above
。
3
、
In the surveillance state press the
“
>>
”
key to switch to the current position
display
,
and fill the value in the orientation of location parameter
(
P6.26-P6.33
)。
4
、
Peform a spindle accurate stop,if there is a devitation,it can be calibrated
through increasing or decreasing the number of pulses.