Chapter 8 Maintenance
74
Chapter 8 Maintenance
Danger
1.
Please do not touch the terminals of driver, which are provided with the high
voltage.
There is the danger of electric shock.
2.
Before power is supplied, please do install the terminal casing well. When the
casing is dismantled, please do cut off the power supply.
There is the danger of electric shock.
3.
Maintenance and inspection cannot be started until the main circuit power
supply is cut off and the CHARGE LED indicator light is confirmed to go out.
There is the danger of residual voltage on the electrolytic capacitor.
4.
Non-professionals are not allowed to do the job of maintenance and inspection.
There is the danger of electric shock.
Caution
1.
As the CMOS integrated circuit is installed on the keypad panel, the control
circuit board and the driving circuit board, please pay special attention when
they are used. If the circuit boards are touched with the finger directly, the
integrated chips on them may be damaged by the electrostatic induction.
2.
Please do not change the connection lines or dismantle the terminal lines when
power is supplied.
There is the danger of electric shock.
3.
Please do not check the signal during operation. Otherwise, the equipment may
be damaged.
8.1 Inspection and Maintenance
Driver is a typical product which combines the power electronics technology with the
microelectronics technology. Therefore, it double features with industrial Equipment
and microelectronics Equipment. The change of environment such as temperature,
humidity, smog and internal components aging will cause kinds of faults to the driver.
For long time reliable operation, daily inspection and regular maintenance (at least 3 or
6 months interval) is needed.