Alpha E-Tec 25R - Installation
Fig. 5.18
5.13 OPTIONAL ALPHA SYSTEM DIVERTER KIT
The Alpha Diverter Kit operates as a hot water priority valve. If the heating is on and there is a hot water demand the valve
will divert the primary hot water to the cylinder until the cylinder sensor is satisfied. The heating will be held off during this
period so it is recommended that a high recovery cylinder is used. The kit comprises of a diverter valve and cylinder sensor.
Installing the kit is simplified due to the direct wiring of the diverter valve and cylinder sensor to the boiler terminal block and
the option of an RF or direct wired Climatic Programmable Boiler Energy Manager should be used to control hot water and
heating (see Section 9 - Wiring Diagram).
When using this kit the hot water cylinder temperature and heating temperature can then be independantly set using the two
thermostat knobs on the boiler control panel or the control dials on the Alpha Climatic control unit if fitted.
Diverter kit ..................................... Part number 6.5500048
Climatic Control Unit Wired ........... Part number 3.022144
Climatic Control Unit RF ................ Part number 3.022143
The Cylinder Sensor supplied with the kit is connected to terminals 36 and 37. See Fig. 3.3.
With the Alpha Diverter kit fitted the optional weather compensation feature can be used to control the central heating flow
temperature.
weather compensation sensor ....... Part number 3.022383
Automatic
by-pass valve
Boiler
150mm max
1000mm min height
Feed and
expansion tank
Vent (22mm min)
Cold feed
(15mm min)
Pump
DHW storage
cylinder
Alpha diverter valve
with cylinder sensor
450mm min height
Heating circuit
A
B
AB
5.14 OPTIONAL ALPHA DHW RELAY KIT
The Alpha DHW relay kit can be used to enable the weather compensation feature for central heating with the optional external
sensor fitted and maintain a set flow temperature during hot water demand to achieve the required cylinder set temperature.
This feature requires the DHW relay kit part No. 3.029422 to be fitted into the control panel as shown in Fig. 5.14.
A 230 Vac connection from the cylinder thermostat is then connected to the DHW relay kit. When hot water is in demand
and the cylinder is below the set point temperature the live signal will activate the relay. The supplied signal cable is then
connected from X2 on the DHW relay kit to X4 on the boiler main PCB. During DHW demand the flow temperature will revert
to the value set using the DHW thermostat knob on the boiler to heat the hot water cylinder.
Note:
The DHW settings on the boiler must be set greater than the cylinder thermostat setting to satisfy the cylinder required
temperature.