3.4 FLUE LENGTHS
A 500 mm or 1000 mm Easy-Flue terminal kit with 90° bend or horizontal terminal is available.
CD 750 mm and 1000 mm flue extensions are available.
Length of Flue Required:-
Rear Flue = wall thi 163 mm (includes terminal).
Side Flue
= wall thi distance between wall and side of 205 mm (left side) or 235 (right side)
(includes terminal).
Vertical Flue = distance from top of boiler side panel to required roof position minus 1000 mm for vertical terminal assembly.
Maximum horizontal flue length = 12 m.
Maximum vertical flue length including terminal is 14 m.
Each additional CD 90° Bend is equivalent to 1.3 m of flue length.
Each CD 45° Bend is equivalent to 0.9 m of flue length.
The CD Vertical Flue terminal assembly is equivalent to 1 m of flue length.
3.3 PHYSICAL DATA
Boiler flow and return connections
mm
Gas connection diameter
mm
Boiler dimensions
Height
mm
Width mm
Depth mm
Clearances for servicing
Bottom
mm
Top (horizontal flue) mm
Top (vertical flue)
mm
Sides mm
Front mm
Recommended hole size for flue pipe
mm
Recommended hole size for instalation from inside the building
mm
Boiler dry lift weight
kg
Boiler operating weight (full of water) approx.
kg
Max. total flue length
Horizontal
m
Max. total flue length
Vertical
m
Flue system diameter
mm
Ambient operating temperature
°C
22
22
600
390
300
250
235
150
5
450
110
130
25
27
12
14
60/100
-5 min. 40 Max.
*
*
with frost protection enabled