4.0 Specifications
Models
Power Line Cords
FP1208-F-5A:
120Vac 3-Conductor NEMA 5-15 power cord (875-698-19)
FP1208-F-5B:
240Vac 3-Conductor Schuko input power cord (876-042-19)
FP1208-F-5C:
240Vac 3-Conductor United Kingdom input power cord (876-046-19)
FP1208-F-5D:
240Vac 3-Conductor Australia/New Zealand input power cord (876-043-19)
FP1208-F-5E
250Vac 3-Conductor Brazilian 14136 input power cord (876-044-19)
Input
AC Input Voltage:
90Vac–264Vac
AC Input Frequency:
50/60Hz
Connection:
IEC 320-C6 3-Prong with cable ties to prevent accidental removal of the line cord.
Surge Protection:
Standards
Level
Telcordia GR-1089
ANSI/IEEE C62.41
IEC 61000-4-5
1.2x50us combination wave, 2kV
Output
Operational Output Power (ONT Load):
8W max.
Output Voltage:
12Vdc nominal
Connection:
RF connector
Mechanical Dimensions
Unit Dimensions for 5, 7.2 or 8Ah Battery
L x W x D (in/mm):
6.6 x 7.5 x 3.2 / 167.6 x 190.5 x 81.3
Unit Weight without battery (lb/kg):
1.2 / 0.54
5.1Ah Battery weight (lb/kg):
3.9 / 1.8
7.2Ah Battery weight (lb/kg):
5.7 / 2.6
8.0Ah Battery weight (lb/kg):
5.73 / 2.76
Estimated Battery Runtimes
1.5W Load
4W Load
5.1Ah Battery (Hrs):
34.2
12.7
7.2Ah Battery (Hrs):
54.4
20.0
8.0Ah Battery (Hrs):
60.7
22.4
Battery type:
Maintenance free, leak-proof, sealed VRLA (valve regulated lead acid)
Visual Indicators
AC Power:
Green LED on: AC power present and powering the ONT
Battery:
Green LED on: Battery powering ONT during AC loss
Green Flashing: Battery powering ONT during AC loss and running low
Replace Battery:
Red LED off: Battery present and working correctly
Red LED on: Replace battery / battery missing
Mute
Green LED on: Lit when Silence Alarm button is pressed.
Audible Status Indicators
Loss of input power:
Single, one second chirp
Low battery:
Single chirp every 15 second
Replace battery:
Double chirp every 15 minutes
Push Buttons
DC Start:
Press and hold when unit is off to start up on battery without AC present
Silence Alarm:
When any audible alarm is on, press this button for at least 1 second and release to silence the audible alarm
until power is cycled
4.1 FlexPoint 1208-F specifications