010-353-B9-001 Rev. A1 (09/2015)
18
Models
Power Line Cords
FP1250-D-8A:
120Vac 3-Conductor NEMA 5-15 power cord (875-698-19)
FP1250-D-8B:
230Vac 3-Conductor Schuko input power cord (876-042-19)
FP1250-D-8C:
230Vac 3-Conductor United Kingdom input power cord (876-046-19)
FP1250-D-8D:
240Vac 3-Conductor Australia/New Zealand input power cord (876-043-19)
FP1250-D-8E:
250Vac 3-Conductor Brazilian 14136 input power cord (876-044-19)
FP1250-D-8-6C:
120Vac 3-Conductor NEMA 5-15 power cord with BC cable (875-698-19)
FP1250-D-8-F:
230Vac 3-Conductor India input power cord (876-045-19)
Input
AC Input Voltage:
90Vac–264Vac
AC Input Frequency:
50/60Hz
Connection:
IEC 320-C6 3-Prong with cable ties to prevent accidental removal of the line cord.
Surge Protection:
Standards
Level
Telcordia GR-1089
ANSI/IEEE C62.41
IEC 61000-4-5
1.2x50us combination wave at 2kV
Output
Operational Output Power (ONT Load):
50W max. continuous, up to 9W continuous on F connector
Output Voltage:
12Vdc nominal
Connections:
7-position connector and F-type coaxial connector
Mechanical Dimensions
Unit Dimensions for 5, 7.2 or 8Ah
Battery L x W x D (in/mm):
6.6 x 7.5 x 3.2 / 167.6 x 190.5 x 81.3
Unit Weight without Battery (lb/kg):
1.4 / 0.64
5.1Ah Battery Weight (lb/kg):
3.9 / 1.8
7.2Ah Battery Weight (lb/kg):
5.7 / 2.6
8.0Ah Battery Weight (lb/kg):
5.73 / 2.6
Estimated Battery Runtimes
36W Load
50W Load
5.1Ah Battery (Hrs):
0.9
0.7
7.2Ah Battery (Hrs):
1.4
1.0
8.0Ah Battery (Hrs):
1.7
1.1
Battery Type:
Maintenance free, leak-proof, sealed VRLA (valve regulated lead acid)
Visual Indicators
AC Power:
Green LED on: AC power present and powering the ONT
Battery:
Green LED on: Battery powering ONT during AC loss
Green Flashing: Battery powering ONT during AC loss and running low
Replace Battery:
Red LED off: Battery present and working correctly
Red LED on: Replace battery / battery missing
Mute
Green LED on: Lit when Silence Alarm button is pressed.
Audible Status Indicators
Loss of Input Power:
Single, one second chirp
Low Battery:
Single chirp every 15 seconds
Replace Battery:
Double chirp every 15 minutes
Push Buttons
DC Start:
Press for at least 1 second when unit is off to start up on battery without AC present
Silence Alarm:
When any audible alarm is on, press this button for at least 1 second and release to silence the audible alarm
until power is cycled.
4.0
Specifications
4.3 Flexpoint 1250-D specifications