background image

5

010-353-B9-001 Rev. A1 (09/2015)

FlexPoint safety and compliance notes

Review the drawings and illustrations contained in this manual before proceeding. If there are any questions 

regarding the safe installation or operation of the system, contact Alpha Technologies or the nearest Alpha 

representative. Save this document for future reference.
To reduce the risk of injury or death, and to ensure the continued safe operation of this product, the following 

symbols have been placed throughout this manual. Where these symbols appear, use extra care and 

attention.

NOTICE:

Follow all safety information within this manual. If there are any questions regarding the 

proper installation of the product, contact Alpha Technologies, 1 800 863 3364.

CAUTION!

• 

Always replace batteries with those of an identical type and rating. Never install untested batteries.

• 

Spent or damaged batteries are environmentally unsafe. Always recycle used batteries. Refer to local 

codes for proper disposal of batteries.

ATTENTION: 

Federal Communications Commission (

FCC) CLASS B Statement

 

CAUTION!

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant 

to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful 

interference in a residential installation. This equipment generates, uses and can radiate radio frequency 

energy and, if not installed and used in accordance with the instructions, may cause harmful interference 

to radio communications. However, there is no guarantee that interference will not occur in a particular 

installation.  If this equipment does cause harmful interference to radio or television reception, which can be 

determined by turning the equipment off and on, the user is encouraged to try to correct the interference by 

one or more of the following measures:

• 

Reorient or relocate the receiving antenna.

• 

Increase the separation between the equipment and  the receiver.

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected.

• 

Consult the dealer or an experienced radio/TV technician for help.

For further information Visit: 

https://www.fcc.gov/guides/interference-defining-source

Changes and modifications not expressly approved by the manufacturer or registrant of this equipment can 

void your authority to operate this equipment under FCC rules.

Battery safety guidelines

• 

Follow all battery manufacturer’s storage and maintenance instructions.

Confirm all FlexPoint unit inventory items are present before beginning the installation process, see 

Section 1.5, FlexPoint 1208-F / 1232-D / 1250-D Inventory

.

Summary of Contents for FP1208-F-5A

Page 1: ...FlexPoint TM Series UPS Technical Manual FlexPoint 1208 F 1232 D 1250 D Series Indoor UPS Effective September 2015...

Page 2: ...ZARD WARNING provides flammability safety information to PREVENT INJURY OR DEATH to the technician or user WARNING FIRE HAZARD WARNING FIRE ELECTRICAL HAZARD ATTENTION The following sections contain i...

Page 3: ...Alpha Technologies or the nearest Alpha representative Alpha shall not be held liable for any damage or injury involving its enclosures power supplies generators batteries or other hardware if used or...

Page 4: ...ery options 8 Table 2 1 12Vdc output connector pin assignments 11 Table 3 1 Audible alarms and visual indicators 14 Table 3 2 FlexPoint battery options 14 Table of Contents FlexPoint safety and compli...

Page 5: ...signed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in...

Page 6: ...0Hz power receptacle provides primary power to the input of the unit The AC voltage is then converted to a usable 12Vdc output The power supply is to be installed within 8 2 4m of an AC receptacle Cur...

Page 7: ...either 32W or 50W respectively of 12Vdc primary and standby power for FTTx and RFoG activity The FP1208 F provides 8W of 12Vdc standby power for RFoG applications 5 1Ah 7 2Ah and 8 0Ah battery options...

Page 8: ...ceptacle Plug the line cord into the receptacle in the unit Secure line cord at one of the cable tie holes with one included cable tie Do not plug the unit into an AC receptacle until the last step of...

Page 9: ...2015 7 48 190 0 mm 3 19 81 0 mm 4 23 107 4 mm 6 57 166 9 mm 2 52 64 0 mm 2 83 71 8 mm 4 29 108 9 mm 3 23 82 0 mm Cover removed for clarity 1 0 Introduction continued 1 6 FlexPoint dimensions Fig 1 5...

Page 10: ...t the cord is easily accessible Always mount the unit in a vertical orientation with 6 15 2 cm of space above and below 2 4 5 10 cm in front and 2 5 cm of space on both sides to provide adequate therm...

Page 11: ...f the installation procedure E Connect the output cable to the 12Vdc output connection 3 and to the coaxial connector 4 Secure in cable dressing holes 5 with the included cable ties 1 2 4 3 3 4 2 Cabl...

Page 12: ...ry in place 3 Connect the battery wires to the battery terminals see Fig 2 5 To ensure correct wire connections verify the battery polarity clip is connected to the negative battery terminal 4 Install...

Page 13: ...tacle Within approximately 30 seconds the alarm should sound for 1 second it may take longer to trigger this alarm if the load is very light or not connected AC mode LED Green will display then turn o...

Page 14: ...er supply needs to be replaced REPLACE BATT LED Red steady ON 2 beeps every 15 minutes The unit automatically initiates a battery test every 180 days If the unit fails the test this alarm is triggered...

Page 15: ...e the test is postponed until those conditions are met If the AC input is lost or the unit is overloaded during the battery test it will be aborted and post poned until conditions are valid Once a bat...

Page 16: ...attery lb kg 1 2 0 54 5 1Ah Battery weight lb kg 3 9 1 8 7 2Ah Battery weight lb kg 5 7 2 6 8 0Ah Battery weight lb kg 5 73 2 76 Estimated Battery Runtimes 1 5W Load 4W Load 5 1Ah Battery Hrs 34 2 12...

Page 17: ...r 5 7 2 or 8Ah Battery L x W x D in mm 6 6 x 7 5 x 3 2 167 6 x 190 5 x 81 3 Unit Weight without Battery lb kg 1 3 0 59 5 1Ah Battery Weight lb kg 3 9 1 8 7 2Ah Battery Weight lb kg 5 7 2 6 8 0Ah Batte...

Page 18: ...7 2 or 8Ah Battery L x W x D in mm 6 6 x 7 5 x 3 2 167 6 x 190 5 x 81 3 Unit Weight without Battery lb kg 1 4 0 64 5 1Ah Battery Weight lb kg 3 9 1 8 7 2Ah Battery Weight lb kg 5 7 2 6 8 0Ah Battery...

Page 19: ......

Page 20: ...se Thorley Bishop s Stortford Hertfordshire CM22 7PA United Kingdom Tel 44 1279 501110 Fax 44 1279 659870 Alphatec Ltd 339 St Andrews St Suite 101 Andrea Chambers P O Box 56468 3307 Limassol Cyprus Te...

Reviews: