7

010-353-B9-001 Rev. A1 (09/2015)

ONT

FlexPoint 1232-D & 1250-D

7-position output cable (Class 2 wiring) is designed to supply 

power to both an ONT and a micro-node with a total of 32W 

and 50W (respectively), via the 7-pin connector and the 

F-type coaxial connector.

FlexPoint 1208-F

F-type connector 8W (max.) to micro-node.

1.0 

Introduction, continued

1.3  System features

• 

The FP1232-D and FP 1250-D units are robust power systems which can provide either 32W or 

50W (respectively) of 12Vdc primary and standby power for FTTx and RFoG activity. The FP1208-F 

provides 8W of 12Vdc standby power for RFoG applications.

• 

5.1Ah, 7.2Ah and 8.0Ah battery options are available for FP1208-F, FP-1232-D and FP1250-D.

• 

All models have customer-replaceable hot-swappable battery.

• 

The battery management system is engineered to provide optimum service life and runtime.

• 

Local visual and audible status indicators.

• 

Remote status alarms.

FlexPoint: Up to 50' (~15.25M)

Network

area

Customer

area

Line cord up to 8'

(2.4meters)

Fig. 1-1, FlexPoint front view

Fig. 1-2, FlexPoint right side view

Fig. 1-3, System block diagram

Summary of Contents for FP1208-F-5A

Page 1: ...FlexPoint TM Series UPS Technical Manual FlexPoint 1208 F 1232 D 1250 D Series Indoor UPS Effective September 2015...

Page 2: ...ZARD WARNING provides flammability safety information to PREVENT INJURY OR DEATH to the technician or user WARNING FIRE HAZARD WARNING FIRE ELECTRICAL HAZARD ATTENTION The following sections contain i...

Page 3: ...Alpha Technologies or the nearest Alpha representative Alpha shall not be held liable for any damage or injury involving its enclosures power supplies generators batteries or other hardware if used or...

Page 4: ...ery options 8 Table 2 1 12Vdc output connector pin assignments 11 Table 3 1 Audible alarms and visual indicators 14 Table 3 2 FlexPoint battery options 14 Table of Contents FlexPoint safety and compli...

Page 5: ...signed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in...

Page 6: ...0Hz power receptacle provides primary power to the input of the unit The AC voltage is then converted to a usable 12Vdc output The power supply is to be installed within 8 2 4m of an AC receptacle Cur...

Page 7: ...either 32W or 50W respectively of 12Vdc primary and standby power for FTTx and RFoG activity The FP1208 F provides 8W of 12Vdc standby power for RFoG applications 5 1Ah 7 2Ah and 8 0Ah battery options...

Page 8: ...ceptacle Plug the line cord into the receptacle in the unit Secure line cord at one of the cable tie holes with one included cable tie Do not plug the unit into an AC receptacle until the last step of...

Page 9: ...2015 7 48 190 0 mm 3 19 81 0 mm 4 23 107 4 mm 6 57 166 9 mm 2 52 64 0 mm 2 83 71 8 mm 4 29 108 9 mm 3 23 82 0 mm Cover removed for clarity 1 0 Introduction continued 1 6 FlexPoint dimensions Fig 1 5...

Page 10: ...t the cord is easily accessible Always mount the unit in a vertical orientation with 6 15 2 cm of space above and below 2 4 5 10 cm in front and 2 5 cm of space on both sides to provide adequate therm...

Page 11: ...f the installation procedure E Connect the output cable to the 12Vdc output connection 3 and to the coaxial connector 4 Secure in cable dressing holes 5 with the included cable ties 1 2 4 3 3 4 2 Cabl...

Page 12: ...ry in place 3 Connect the battery wires to the battery terminals see Fig 2 5 To ensure correct wire connections verify the battery polarity clip is connected to the negative battery terminal 4 Install...

Page 13: ...tacle Within approximately 30 seconds the alarm should sound for 1 second it may take longer to trigger this alarm if the load is very light or not connected AC mode LED Green will display then turn o...

Page 14: ...er supply needs to be replaced REPLACE BATT LED Red steady ON 2 beeps every 15 minutes The unit automatically initiates a battery test every 180 days If the unit fails the test this alarm is triggered...

Page 15: ...e the test is postponed until those conditions are met If the AC input is lost or the unit is overloaded during the battery test it will be aborted and post poned until conditions are valid Once a bat...

Page 16: ...attery lb kg 1 2 0 54 5 1Ah Battery weight lb kg 3 9 1 8 7 2Ah Battery weight lb kg 5 7 2 6 8 0Ah Battery weight lb kg 5 73 2 76 Estimated Battery Runtimes 1 5W Load 4W Load 5 1Ah Battery Hrs 34 2 12...

Page 17: ...r 5 7 2 or 8Ah Battery L x W x D in mm 6 6 x 7 5 x 3 2 167 6 x 190 5 x 81 3 Unit Weight without Battery lb kg 1 3 0 59 5 1Ah Battery Weight lb kg 3 9 1 8 7 2Ah Battery Weight lb kg 5 7 2 6 8 0Ah Batte...

Page 18: ...7 2 or 8Ah Battery L x W x D in mm 6 6 x 7 5 x 3 2 167 6 x 190 5 x 81 3 Unit Weight without Battery lb kg 1 4 0 64 5 1Ah Battery Weight lb kg 3 9 1 8 7 2Ah Battery Weight lb kg 5 7 2 6 8 0Ah Battery...