27
5.9 USER INFORMATION
The User must be advised (and demonstrated if necessary) of the following important points:-
1. How to light and turn off the boiler and how to operate the system controls.
2. The importance of annual servicing of the boiler to ensure safe and efficient ope ation.
3. That any servicing or replacement of parts must only be carried out by a Gas Safe registered engineer.
4. Ensure that the boiler controls and room thermostat (if fitted) are set to the User's requirement .
5. Tell the User about the sealed system pressure.
6. Tell the User that if the electrical supply is on and the boiler has not operated for 24 hours for heating or hot water, the
pump will automatically operate for 30 seconds.
7. Explain to the User that an internal frost thermostat is fitted in the boile , and that the electrical supply to the boiler must
be left on for the thermostat to operate, i.e. the boiler must be set to standby.
8. Explain to the User that in certain weather conditions the terminal will emit a plume of steam, i.e. water vapour. This is
safe and quite normal.
9. Show the User the position of the pressure relief valve and condensate discharge pipes.
10. Hand the User's instructions to the User.
11. Ensure the Benchmark Checklist at the back of these instructions has been completed after the boiler has been
installed and commissioned.
Note:
It is a requirement that the installation is registered by the installer through the Gas Safe Gas Work Notification
Scheme.
12. Leave these Installation and Servicing instructions with the User for use on future calls.
5.10 INFORMATION MENU
By pressing the info button (item 4 in Fig. 26) the information menu is accessed, this will then show the information according
to the table below.
Alpha InTec S - Commissioning
Info Menu
(d - prefix
d0
d1
d2
d3
d4
d5
d6
d7
d8
d9
Information
Not used
Flame signal
Central heating water temperature leaving the boiler
Domestic hot water cylinder temperature sensor - Alpha Diverter valve kit fitte
Central heating set point temperature
Domestic hot water set point temperature
Weather compensation probe temperature (value flashes if negati e) - Alpha Diverter valve kit fitte
N/A
Not used
Fault history - by rotating the CH knob (item 6 in Fig. 25) in this menu the last fi e faults will be displayed
Units
Shown
m
A x 10 (approx)
°C
°C
°C
°C
°C
Error code