6
Alpha InTec S - Technical Data
2.5 AVAILABLE PUMP HEAD FOR CENTRAL HEATING
Flow (litres/hr)
Head (metres)
200
600
1000
1400
800
1200
1600
400
0
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
Fig. 1
2.6 ELECTRICAL CONNECTIONS
230 V ~ 50 Hz CONNECTIONS
LOW VOLTAGE CONNECTIONS ONLY
(optional Climatic or RF Climatic control)
Remove the resistor between terminal block
connections 8 and 9 to connect optional
storage tank NTC sensor.
External
probe
(optional)
Alpha
Climatic control
(optional)
Storage tank
NTC sensor
(optional)
RF Climatic
control receiver
(optional)
Low voltage terminal block
8
9
10
11
12
13
RF Climatic
control (optional)
+
_
230 V ~ Control connections
WARNING
Ensure Control wires are
connected correctly - refer to the
control and boiler instructions for
connection details.
2
1
3
4
5
Blue
Brown
Black
Grey
White
Optional Alpha controls
Resistor
Supply
230 V ~
50 Hz
Blue
G/Y
Brown
Switched Live
DHW Of
f
DHW On
CH On
Link
(Red)
L N
1 2
3 4 5 6 7
Mains terminal block
Alpha
Diverter
valve
connection
(optional)
Remove the link between 1 and 2 if the
optional Alpha Climatic control or 230 V
room thermostat is used.
2.4 FLUE LENGTHS
CD Easy-Flue 500 mm with terminal and 90° bend. A CD Easy-Flue 1000 mm with terminal and 90° bend is also available.
CD 750 mm and 1000 mm flue xtensions are available.
Length of Flue Required:-
Rear Flue = wall thi 160 mm (includes terminal). This is without back frame, add 45 mm if the wall jig is used.
Side Flue
= wall thi distance between wall and side of 245 mm (includes terminal)
Vertical Flue = distance from top of boiler side panel to required roof position minus 1000 mm for vertical terminal assembly
Maximum horizontal flue length = 12 m
Maximum vertical flue length including te minal is 14 m.
Each additional CD 90° Bend is equivalent to 1.3 m of flue length
Each CD 45° Bend is equivalent to 0.9 m of flue length
The CD Vertical Flue terminal assembly is equivalent to 1 m of flue length
Note: This Appliance Must Be Earthed
Optional integral two channel controls are
available if required.
Note:
Only use the Alpha two channel
controls.
Do not fit a y single channel
controls.