3
Min. 1.0
Min. 0.22
2
TECHNICAL DATA
Alpha SolarSmart 150 - Technical Data
2.2
SOLAR COLLECTOR SYSTEM - Per Panel
Max.18.0
Max. 4.0
2.1
DHW SYSTEM
5.5 bar
12 bar
0.1 bar
15 mm
15 mm
152 L
12 L at 2.5 bar
2.5 bar
90°C/7 bar
6 bar
70°C (158°F)
Solar Cylinder
Max. Hot Water Working Pressure
Max. Mains Inlet Pressure
(inlet of pressure reducing valve)
Min. Mains Water Pressure
Mains Inlet Connection
DHW Outlet Connection
DHW Cylinder Capacity
Expansion Vessel Size (pre-charge press.)
Pressure Reducing Valve Setting
Temperature and Pressure Relief Valve
Expansion Relief Valve Setting
Flow Rate
L/min
gal/min
Max. Outlet Water Temp. (Approx.)
15 mm
15 mm
8 bar
0.32 L
15 mm
22 mm
6 bar
11 L
9 L
110 W/K
6 bar
Drain Back Unit (DBU)
DHW Circuit:
Flow Connection
Return Connection
Max. Working Pressure
Plate Heat Exchanger Content
Collector Circuit:
Flow Connection
Return Connection
Max. Working Pressure
Vessel Size
Max. Filled Content
Heat Transfer Capacity
Expansion Relief Valve
Reference to WRC-NSF Test Procedure 1.50.220 using a 30 kW boiler. Time to reheat water store by 55°C - 25
minutes. Reheat time for 70% of store - 18 minutes
Note: Copper pipe MUST be used between the
cylinder, drain back unit and collectors.
2.5
2.26
45 Gross - 44 Nett
8
95
5
4
Aluminium Pressing
50
0.037
Aluminium Black Powder Coated
10 k
12 mm
15 mm
5.4 GJ/yr (1500 kWh/yr) (2 panels)
74%
3.629
0.9
@80 l/h - 9 kPa
Same as Supporting Roof Structure
Wind Speed 27 m/s - Snow Load 1.9 kN/m
2
4 x 2.3 m
2
= 9.2 m
2
Landscape
1120 x 2230 x 92
1.10
1030 x 2140 x 0.5
30° Min (90° Max)
Portrait
2230 x 1120 x 92
1.16
2140 x 1030 x 0.5
20° Min (90° Max)
Type:
Dimensions
Total Surface Area
m²
Aperture Area
m²
Length x Width x Thickness
mm
Water Content
L
Lift Weight
kg
Hydraulics
Maximum Pressure
bar
Absorber
Aluminium Cover and Copper Pipe
(Length x Width x Depth)
mm
Spectral Selective Layer
Absorption Coefficient
%
Emission f
%
Glass
Transparent, Hardened - Thickness
mm
Collector Housing
Material
Insulation
Thickness
mm
Thermal conduction coefficient
W/mk
Cover Frame
Material
Temperature Sensor
Type - NTC
Ohm
Connections
Pre-mounted Flexible Hoses
Return to DBU
mm
Flow from DBU
mm
Roof Slope
Energy Performance (System with 90L tank)
Zero Loss Collector Efficiency (No)
Collector Heat Loss Coefficient (a1)
W/m²k
Aperture to Gross Collector Area Ratio
Collector Pressure Drop
Max. Wind and Snow Load
Pitched roof
Flat roof
Max. Collector Array
Profile of collector when fitted using an Alpha flashing kit protrudes approximately 30 mm to 60 mm above the
tiles (depends upon type of tile used)