29
Alpine TR42 Direct Vent Gas Fireplace
SERVICE INFORMATION
1)Open the bottom valve door
2)Shut off the gas supply
3)Disconnect the inlet gas line (3/4”
wrench)
4)Disconnect the 2 TP wires from the
valve
5)Disconnect the 2 TH wires from the
valve
6)Disconnect the pilot tube from the valve
(use a 7/16” wrench)
7)Disconnect the thermocouple from the
valve (use 9mm wrench)
8)Disconnect the main burner tube
(11/16” wrench)
9)Remove the 2 square nuts securing the
valve holder to the floor
10)Remove the valve from the appliance
REMOVING VALVE
INSTALLING VALVE
1)Mount valve to valve holder
2)Place valve / valve holder back into
position
3)Secure valve with 2 square nuts
4)Connect main burner gas tube (use
11/16” wrench)
5)Connect the thermocouple to the valve
(use a 9mm wrench)
6)Connect the pilot tube to the valve (use
7/16” wrench)
7)Connect the TH wires to the valve
8)Connect the TP wires to the valve
9)Connect the main gas supply to the
valve (use a 3/4” wrench)
10)Double check to make sure all
connection are complete and tight
11)Restore gas supply
12)Using a soap solution, check for leaks
in main gas supply.
13)Make sure the toggle switch is in the
“OFF” Position
14)Ignite pilot and check for leaks in pilot
line
15)Ignite main burner and check for leaks
in main burner tube.
CAUTION: Never use an open flame to
check for gas leaks. Always use a soap
solution to check for leaks.