background image

32 

Alpine TR42 Direct Vent Gas Fireplace 

LIMITED LIFETIME WARRANTY 

 

COVERAGE - This Limited Warrranty is issued by Alpine Gas Fireplaces, a division of Alpine Supply Company ("Alpine"), and extends only to the original 

consumer purchaser. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO 

STATE. 
LIMITED ONE YEAR WARRANTY 
 The Alpine Gas Fireplace is warranted to be free of defects in materials and workmanship (does not include installation materials and installation labor) for a 

period of one (1) year from the date of purchase when installed and used in accordance with the recommendations in the installation and operation instruc-

tions for the fireplace. The determination as to the existence of a defect and whether or not that defect is material shall be made in accordance with accepted 

industry standards. Defective parts will be repaired or replaced at Alpine's option. Parts which are returned to Alpine and found defective on inspection will be 

repaired, or replaced with a new part, without charge to the purchaser as long as the part is still under warranty. All shipping charges will be paid by  the 

purchaser, and all new or repaired parts shipped to the purchaser shall be shipped freight collect (F.O.B. Lehi, Utah). Service calls ordered by the customer, 

repairs, or parts  which do not qualify for warranty shall be charged to the customer at then current rates for labor, parts and transportation.  
LIMITED LIFETIME WARRANTY 
In addition to the one year warranty described above, the firebox of the Alpine Gas Fireplace is warranted for life against through wall perforation when in-

stalled and used in strict compliance with the recommendations in the installation and operation instructions for the fireplace, provided that the blower has 

been installed and been kept operable and working whenever the fireplace has been in use, and there has been an approved and tested vent cap in place on 

the chimney to prevent moisture from coming down the flue and causing the rusting of the firebox or other components. For purposes of this lifetime war-

ranty, burnout means only the eroding of the interior metal floor, top, walls or heat exchanger in the top of the appliance, solely by fire action, to the point that 

the erosion has resulted in one or more holes from inside of the firebox into the surrounding hot air chambers of the appliance. This lifetime warranty does 

not cover warping or rusting of the firebox. The damaged part or parts of the firebox will be repaired or replaced at Alpine's option. Parts which are returned 

to Alpine and are found damaged by burnout on inspection will be repaired, or replaced with a new part, without charge to the purchaser as long as the unit is 

still under warranty. All shipping charges shall be paid by the purchaser, and all new or repaired parts shipped to the customer shall be shipped freight col-

lect (F.O.B. Lehi, Utah). If the damaged part or parts under warranty cannot reasonably be removed and shipped to Alpine for replacement or repair, Alpine 

will provide a serviceman to correct the defect at the location where the  gas fireplace is installed without charge to the purchaser for labor or materials, pro-

vided that the purchaser shall pay a reasonable charge for the transportation of the serviceman and needed parts and equipment from the nearest Alpine 

service center to the location of the appliance and return. 
LIMITATIONS
 - These one year and limited lifetime warranties are in lieu of all other express warranties. ALL IMPLIED WARRANTIES, INCLUDING ANY IM-

PLIED WARRANTIES OF MERCHANTABILITY OR OF FITNESS FOR ANY PARTICULAR PURPOSE, ARE SPECIFICALLY LIMITED TO A TERM OF ONE (1) YEAR 

FROM THE DATE OF PURCHASE (SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITA-

TION MAY NOT APPLY TO YOU). Alpine neither assumes nor authorizes any other person to assume for it, any additional liability in connection with the sale, 

installation, replacement, or repair of the appliance.  
EXCLUSIONS
  Alpine shall be held free and harmless from liability damage to property or injury to persons related to the installation or operation, proper or 

improper, of the appliance. THESE ONE YEAR AND  LIMITED LIFETIME  WARRANTIES DO NOT COVER, NOR DOES ALPINE ASSUME, RESPONSIBILITY FOR 

INCIDENTAL, SECONDARY, OR CONSEQUENTIAL DAMAGES. ( SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CON-

SEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.) 
 
These one year and  limited lifetime warranties do not cover:  
1.  Damage or malfunction resulting from accident, negligence, abuse, alteration, unauthorized service, damage during transportation, shipping or damage 

caused by external fire, floods, acts of God, or any other casualty. 
2.  Damage or malfunction resulting from failure to follow the installation or operating instructions provided with the fireplace unit.  
3.  Damages or defects in any parts, equipment, accessories, materials, or items not manufactured, sold, or supplied by Alpine, or any damage resulting from 

the use of such items, which are used on or in connection with the fireplace unit. 
4.  Damage to or defects in any glass windows or internal or external finishes,  or any damage resulting there from, except as an examination by the pur-

chaser may reveal at the time of delivery of the appliance and is reported immediately to Alpine. 
5. Any expansion and contraction noises commonly found in heating equipment. 
6. Damage or malfunction caused by trees or bushes located in the proximity of the vent or vent termination.  
  
PROCEDURE TO OBTAIN PERFORMANCE UNDER WARRANTY  It is recommended that you first contact your local dealer as the dealer may be able to assist 

you with warranty or other service work. In any case, the following procedure must be followed for any and all warranty work; 
If damage occurs or a defect is discovered which you believe is covered by this limited warranty, you must promptly notify Alpine of the damage or defect in 

writing and provide reasonably satisfactory proof of the date of purchase of the appliance. All claims made by you under this warranty should be directed to 

Alpine at the address below. The written notice must contain the name, address and phone number of the customer, as well as the name of the dealer, the 

serial  number of the appliance and the date purchased. Failure to give timely notice to Alpine of any material damage or defect will result in that damage or 

defect being excluded from coverage.  
Upon receipt Alpine will, within 60 days, repair, replace or service the parts or unit as covered by this Limited Warranty. Exceptions to this may be delays that 

are caused by acts of God, labor problems or material shortages. 

ALPINE GAS FIREPLACES 

(801)768-8411 

782 West State Street 

 

www.alpinegasfireplaces.com 

Lehi, 

Utah 

84043     

WARRANTY 

Summary of Contents for TR42 - LP TAMARRON

Page 1: ...s of life Improper installation adjustment alteration service or maintenance can cause property damage personal injury or loss of life INSTALLER PLEASE LEAVE THIS MANUAL WITH THE CUSTOMER HOMEOWNER PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE These gas appliances have been tested in accordance with National Safety Standards and have been certified by Intertek for installation operation as d...

Page 2: ...2 Alpine TR42 Direct Vent Gas Fireplace ...

Page 3: ...rranty 32 GENERAL INFORMATION Rating Plate 4 Before Starting 5 General Safety Information 5 System Specifications 6 Derating the Burner 6 INSTALLATION REQUIREMENTS Locating the Fireplace 6 Gas Line Installation 7 Clearances 7 Mantel Clearances 7 Hearth Materials 7 Framing and Finishing 8 VENTING Venting Planning 9 Venting Components List 9 Vent Termination Clearances 10 Horizontal Vertical Compone...

Page 4: ... with air filters Electrical supply 120VAC 3 5 Amps 60Hz This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes See owner s manual for details This appliance is not convertible for use with other gases unless a certified kit is used Thi...

Page 5: ... with local codes or in the absence of local codes with the current National Fuel Gas Code ANSI Z223 1 installation code 2 The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the current National Electrical Code ANSI NFPA 70 3 This appliance must be connected to the specified vent and termination cap to the outside of the ...

Page 6: ...urdily constructed platform 3 If the appliance is to be installed on carpeting combustible vinyl tiling or any other combustible surface other than wood flooring a wood panel or metal panel must be installed on top of the existing flooring The panel must extend the full width and depth of appliance 4 The Alpine TR42 fireplace can be installed into many different applications See Figure 1 for examp...

Page 7: ...t and manifold pressures should be checked using the valve pressure ports on the control valve CLEARANCES IMPORTANT Clearances listed in this manual must be adhered to strictly Failure to maintain these listed clearances of the fireplace and venting system can re sult in a house fire Clearance to Combustibles from Fireplace Spacers 0 Fireplace Floor 0 Ceiling 18 Ceiling Flex Vent 24 Side Mantel Le...

Page 8: ...the home to prevent cold air infil tration through the fireplace chassis Check with your local building official for any additional local requirements e g vapor barriers drywall Never insulate the fire place itself NAILING TABS MUST BE BENT OUT BEFORE FIREPLACE IS INSERTED INTO FRAMING THERE ARE FOUR NAILING TABS 3 The fireplace is equipped with four nailing tabs which must be bent out before inse...

Page 9: ...options regarding proper placement of the vent termination In all cases adequate combustion and ventilation air must be available for the fireplace Never block the termina tion cap Make sure foliage does not grow around the termination cap In all cases follow the clearances listed on page 8 of this manual NOTE Never connect this gas appliance to a chimney flue serving a separate solid fuel burning...

Page 10: ...thin 3 M Clearance above paved sidewalk or a paved driveway located on public property min 84 N Clearance under a veranda porch deck or balcony min 12 P Clearance to obstructions in front of the termination such as bushes fences sheds decks other structures is 24 Note A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and ser...

Page 11: ...f vinyl is to be used a vinyl siding standoff should also be used If brick or rock is to be applied to the exterior of the home make sure that the cap is extended to the thickness of the brick or rock The Terminal must never be recessed into the wall A brick standoff is available for this application The following is a list of components required for a basic vertical termination installation 1 Ver...

Page 12: ...elbows may be used NOTE A vent restrictor must be installed in the fireplace if the vertical height is more than 12 feet Only Simpson Duravent GS Piping 4 x 6 5 8 May be Used on This Appliance Piping Clearances Vertical Pipe 1 1 2 to Combustibles Horizontal Pipe 2 To Combustibles Top 1 To Combustibles Sides 1 2 To Combustibles Bottom VENTING ...

Page 13: ...H1 max V2 min 1 FT 3 FT 5 FT 3 FT 3 FT 2 FT 5 FT 5 FT 5 FT 3 FT 3 FT 10 FT 5 FT 10 FT 3 FT NOTE Horizontal Piping Must Maintain a 1 4 Rise Per Foot Piping Clearances Vertical Pipe 1 1 2 to Combustibles Horizontal Pipe 2 To Combustibles Top 1 To Combustibles Sides 1 2 To Combustibles Bottom VENTING ...

Page 14: ... Degree Elbow Vertical Horizontal 1 FT 3 FT 2 FT 8 FT 3 FT 16 FT NOTE Horizontal piping must maintain a 1 4 rise per foot Piping Clearances Vertical Pipe 1 1 2 to Combustibles Horizontal Pipe 2 To Combustibles Top 1 To Combustibles Sides 1 2 To Combustibles Bottom VENTING ...

Page 15: ...2 to Combustibles Horizontal Pipe 2 To Combustibles Top 1 To Combustibles Sides 1 2 To Combustibles Bottom Horizontal Venting With Three 3 90 Degree Elbows V min H max H H1 max 1 FT 3 FT 6 FT 2 FT 4 FT 8 FT 3 FT 6 FT 12 FT 4 FT 8 FT 16 FT 5 FT 16 FT 16 FT NOTE Horizontal Piping Must Maintain A 1 4 Rise Per Foot VENTING ...

Page 16: ...pe 1 1 2 to Combustibles Horizontal Pipe 2 To Combustibles Top 1 To Combustibles Sides 1 2 To Combustibles Bottom Horizontal Venting With Two 2 90 Degree Elbows V min H H1 max 3 FT 8 FT 4 FT 10 FT 5 FT 12 FT NOTE Horizontal Piping Must Maintain A 1 4 Rise Per Foot VENTING ...

Page 17: ...li con Fig 11 Applying Sealant NOTE Clearances to combustibles from the vent pipe must be adhered to See the table below for proper clearances Horizontal Venting Clearances TOP OF PIPE 2 to combustibles SIDES OF PIPE 1 to combustibles BOTTOM OF PIPE 1 2 to combustibles 4 Install the vertical pipe needed followed by the elbow to achieve the pre determined exit height and then extend the horizontal ...

Page 18: ...a small hole at this point Next drop a plumb bob from the roof to the hole previously drilled in the ceiling and mark the spot where the vent will penetrate the roof Determine if ceiling joists roof rafters or other framing will obstruct the venting system You may choose to relocate the fireplace or offset the venting to avoid cutting framing members see figure 16 F ir e s to p F la s h in g Fig 1...

Page 19: ... the vent is vertical and secure the base of the flashing with roofing nails Slide the storm collar over the pipe section and seal with a mastic type sealant 8 Install the vent cap by twist locking it in place See Offset Table for additional details fig 19 Fig 18 Vent Height Table Roof Pitch Minimum Vent Height Above Roof Line Flat to 9 12 2 9 12 to 10 12 2 1 2 10 12 to 11 12 3 1 4 11 12 to 12 12 ...

Page 20: ... of 2 horizontal run which will accomplish most exterior wall applications 2 of vertical rise will accommodate up to 3 of horizontal run which is the maximum horizontal run allowable with flex vent Only one 90 transition may be used with the flex vent taking it from the vertical to the horizontal Offsetting in the horizontal plane is not allowed INSTALLING FLEX VENT Horizontal Venting With One 90 ...

Page 21: ...ted with the power switch for the optional blower If this choice is made a DIVIDED double gang electrical box must be installed A standard non divided double gang box cannot be used NOTE Electrical wiring must be installed by a licensed electrician NOTE The appliance must be electrically grounded in accordance with the local codes or in the absence of local codes with the current National Electric...

Page 22: ...ve they will strip Note Local codes need to be followed when installing any electrical appliance If conflicts between this manual and local electrical codes exist Local codes always prevail LO H I TP TH TP TH PILOT To wall switch remote control or thermostat To thermopile Fig 20 Millivolt System LOG INSTALLATION Fig 22 Side Logs Locate the back log 42 1 and position it over the locating pins on th...

Page 23: ...place it directly behind the burner ports along the front of the burner NOTE DO NOT COVER BURNER PORTS You may cover the dead areas on either side to hide the log pads and burner fig 24 Fig 25 Right Top Twig Locate the right top twig 42 6 and place its large end flat side down onto the pad of the right side log Next place the notch at the end of the log against the inside of the second from the ri...

Page 24: ...factory Little or no adjustment may be required for natural gas Propane will perform very differently at different altitudes and from different fuel suppliers Some adjustment will most likely be needed for an appliance burning propane The flame should have a blue base with yellow tips A dark orange flame with sooting and black smoke indicates a lack of primary air The primary air shutter is locate...

Page 25: ... table on page 14 of this manual for maximum wire runs 2 Connect the wires to the gas valve see figure 35 3 Follow the installation instructions included with the remote control kit LO H I TP TH TP TH PILOT To wall switch remote control or thermostat To thermopile Fig 35 Gas Valve Connection A wall thermostat may be installed if desired Follow the wire routing instructions on page 14 of this manua...

Page 26: ...which has been under water This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air CAUTION Hot while in operation Do not touch Keep children clothing furniture gasoline and other liquids having flammable vapors away Keep burner and control compartment clean See installation and operating instructions accompanying a...

Page 27: ...urn off the main burner 2 Turn the main gas control clockwise to the OFF position SHUTDOWN PROCEDURE FIREPLACE MAINTENANCE 1 Before performing any service on the appliance ensure the gas has been completely shut off the unit cooled and the electricity shut off to the appliance 2 The burner and valve control compartments must be cleaned annually A vacuum with a brush attachment works well The logs ...

Page 28: ...chnician Glass Clip Glass with Gasket Flame should engulf the top 3 8 to 1 2 Quick Drop out Thermocouple Pilot Thermopile Fig 36 Pilot Flame Characteristics Your fireplace is supplied with a 35 1 8 x 22 1 2 high temperature 5mm ceramic glass panel that is capable of withstanding the highest heat that your fireplace can pro duce Never attempt to use another type of glass or other material If your g...

Page 29: ...Place valve valve holder back into position 3 Secure valve with 2 square nuts 4 Connect main burner gas tube use 11 16 wrench 5 Connect the thermocouple to the valve use a 9mm wrench 6 Connect the pilot tube to the valve use 7 16 wrench 7 Connect the TH wires to the valve 8 Connect the TP wires to the valve 9 Connect the main gas supply to the valve use a 3 4 wrench 10 Double check to make sure al...

Page 30: ...at Gas 08991 S I T Regulator L P 08221 Thermodisc 180 F 37100 Burner Nat Gas Prop 04046 Piezo Igniter 04080 Door Extension Spring 04038 Pilot Assembly N G 05082 Pilot Orifice L P 06095 Bottom Door Hinge 08501 Remote Control 24500 Top Door 24502 Bottom Door 24504 Glass Trim Arch REPLACEMENT PARTS LIST 24506 Glass Trim Standard 24510 Face Top Arch 08261 Programmable Thermostat 08260 Thermostat 430 9...

Page 31: ...alve terminals are tight and thermopile and thermocouple are fully inserted into pilot bracket Check switch wires to make sure they are not grounding Check thermopile with millivolt meter Take reading at thermopile terminals of valve TP TPTH Should read 250 millivolts minimum while thermopile has pilot flame on it With the pilot ignited turn valve knob to on Take reading at TP TPTH with on off swi...

Page 32: ...ed parts and equipment from the nearest Alpine service center to the location of the appliance and return LIMITATIONS These one year and limited lifetime warranties are in lieu of all other express warranties ALL IMPLIED WARRANTIES INCLUDING ANY IM PLIED WARRANTIES OF MERCHANTABILITY OR OF FITNESS FOR ANY PARTICULAR PURPOSE ARE SPECIFICALLY LIMITED TO A TERM OF ONE 1 YEAR FROM THE DATE OF PURCHASE...