hypercharger - Operation Instructions and Installation Guide
Version 1-1C
Page 12 of 57
3
Product
description
All rights reserved. The reproduction of this document, also partially, is allowed only with authorization by alpitronic s.r.l.
Type
W1 [mm]
D1 [mm]
D2 [mm]
D3[mm]
L [mm]
HYC_075, HYC_150
854
1100
350
1000
420
HYC_225, HYC_300
854
1100
350
1000
732
Table 3:
Distances to keep free for service
Attention
The legal minimum widths for escape routes must be respected in any
case.
To allow easy replacement of the power-stacks, a clearance of at least 110cm must be
available on the left side (see D1).
At least a distance of 1100mm (D1) and 1000mm (D3) must be maintained in front of the
ventilation grilles to not impair the circulation of the supply and exhaust air. It must also be
prevented that the exhaust air is reintroduced into the supply air circuit.
Impairments to the air circulation may lead to a reduced efficiency of the charging station.
3.3. Cable reach
In its default configuration, the hypercharger comes with a cable length of 350cm. The
following figure shows the operating radius (3m) of the cables for the two DC outlets of the
hypercharger.
Figure 7:
Cable reach for the two DC outlets of the hypercharger