Electric Bolt
EB1001 - Instructions
15
126.5
203
57.5
9.5
40
14
172
3
AU
TO
LO
CK
TIM
ED
EL
AY
SE
TT
ING
0
SE
C
3
SE
C
6
SE
C
9
SE
C
1
2
ON OF
F
1
2
ON OF
F
1
2
ON OF
F
1
2
ON OF
F
17
9.5
TECHNICAL INFORMATION
Power to Lock/Fail open.
Stainless steel bolt - diameter 15mm
- throw 15mm
Voltage required
12vDC
Activating current
1.0A
Holding current
250 mA
Fully protected against transients and
reverse polarity
The Autolock Time Delay can be set for
0, 3, 6 or 9 seconds.
Monitoring - Door position switch (DSS)
- Bolt position indicator
GENERAL INSTALLATION
INSTRUCTIONS
Ensure you have the following:-
- Strike plate
- Electric bolt
All rebate strips and/or frame stops
should be fitted before starting.
A 2 amp Power Supply should be
provided to ensure there is a Full 1
amp for the bolt. This should allow for
a basic Access System and a back up
battery to be connected to the same
source.
WARNING - THE CONNECTION
OF AN INCORRECT VOLTAGE
MAY RESULT IN DAMAGE NOT
COVERED BY THE PRODUCT
WARRANTY.
The selection of appropriate power
supply cable is very important to
ensure lock receives sufficient power
to operate.
First Choice for
Locking Solutions
01202 676262
01202 680101
alpro@iecltd.co.uk
www.alpro.co.uk
T
F
E
W
1
2
4
3
alpro
®
Bolt Face Plate 203 x 34 x 3mm
Strike Plate 98 x 34 x 3mm