background image

Electric Strike

AL110

PACK CONTENTS

MOUNTING STEPS OF STRIKE

INSTALL ON METAL OR ALUMINUM DOOR FRAME

DOOR LATCH POSITION

For aluminum or metal door frame brackets are 

supplied for assembly, refer to Figure 2. For timber 
door frame refer to Figure 3. mark and drill the hole 
sizes as indicated on Figure 2 and Figure 3.

Make sure electrical connections are followed 

correctly.

When the door is closed, ensure that there is no 

pressure on the front face of strike keeper.

When all the above checks are completed, secure 

the strike with supplied screws and recheck 
operation.

As shown in Figure 1, there must be a 1mm gap between the door latch 
and the front face of strike keeper to prevent the door from exerting 
pressure on the keeper when door is closed.

Read all instructions before starting installation

POWER INPUT 12 VDC or 24 VDC SUPPLY:

x 4

x 2

x 2

Remove 

rubber plug 

prior to 

assembly of 

extension lips 

(2 places)

Depth of lip 

cutout will 

vary due to 

width of door 

frame and 

mounting 

technique

25mm, 50mm, 

75mm, 

extension lips 

are available 

options

Fig.1

Fig.2

Note: There is no polarity on power input. AL110 

model is not equipped with monitoring sensor.

RED

RED

YELLOW BLUE
BLUE YELLOW
BLACK

BLACK

DSS (Door Status Sensor) BLACK (COM) BLUE (NO) 
ORANGE (NC)
DSS contact rating: max, current 100 mA, max. 
voltage 30 vDC

1

 

2

 

3

 

4

 

 

12 vDC/ 
200 mA

24 vDC/ 
100 mA