ALTEC AIR, LLC
P1500W Series Air Dryers User’s Guide
Page 66 of 101
P011787 – Rev. R
9.10.2
Pull the ring handle on the
Safety Relief Valve to verify
air pressure is released.
9.10.3
Release ring handle and
verify that no air is leaking
from the valve.
9.10.4
Close Front Panel.
If the Safety Relief Valve fails either test described, it must be replaced. See sections 11.2
for part detail and 11.5 for ordering information.
9.11 Testing Compressor ON/OFF Cycling
9.11.1
Open Front Panel
(section 8.6 ).
9.11.2
When the Unit Screen
(8.2.5.1 ) appears on the
display, press the
HOLD
Button
on the Front Panel to
freeze that screen.
With Compressor running:
9.11.3
Verify the Compressor
shuts down when the tank
pressure (
TANK
) reaches
90.0 PSI
.
If the tank pressure (TANK) fails
to reach 90 PSI, see section 0for
troubleshooting information.
With Compressor NOT running: