ALTEC AIR, LLC
P1500W Series Air Dryers User’s Guide
Page 57 of 101
P011787 – Rev. R
3.2 or below
for the P1502W, P1502WLP & P1502WHP models
9.2.4
Close Front Panel.
If the Compressor measures over running amps indicated above, see section
13.16 for troubleshooting information.
9.3 Measuring Compressor Voltage
9.3.1
Power the air dryer
OFF
(section
Error! Reference source not found.
).
9.3.2
Open Front Panel (section 8.6 ).
9.3.3
Depressurize the air dryer (section 8.7 ).
9.3.4
Locate wire #5 at the solid
state relay and wire #6 on
Control Board.
9.3.5
Lift plastic cover on
Control Board over wire #6.
9.3.6
Power the air dryer ON
(section
Error! Reference source not found.
).
9.3.7
Use a Voltmeter to measure
the voltage:
9.3.7.1
Place the probes over
terminals for wire #5
and wire #6.
The voltage should measure:
110 - 125 VAC
for the
WARNING!
Extreme care should be exercised to avoid contact with live
electrical circuits.
It is highly recommended that you remove all
jewelry before performing any procedures.
Summary of Contents for PUREGAS P1500W Series
Page 2: ......