reading is lower than the
Low Outlet Pressure
Alarm set point (above)
Pressure (
OUTP
)
reading is under verified
Low Outlet Pressure
Alarm set point for more
than 1 minute and fails
to create an alarm.
13.9 High Humidity
Possible Cause
Check
Corrective Action
Low System Pressure
Verify System Pressure
(section
Error!
Reference source not
found.
)
Adjust System Pressure.
(section
Error!
Reference source not
found.
)
Low Flow Rate
Verify Flow Rate
(
FLOW
) reading is low
(section
Error!
Reference source not
found.
)
Install the included
Precision Bleed Orifice
fitting to maintain a
constant air flow.
(section
Error!
Reference source not
found.
)
Raise capacity control
setting to 90 PSI.
(section 6.5.13)
High Humidity Alarm
set point too low
Verify High Humidity
Alarm set point
(section
Error!
Reference source not
found.
)
If Flow Rate is low,
allowing a higher alarm
set point (up to 10%)
will allow dryer to run
Raise High Humidity
Alarm set point
(section
Error!
Reference source not
found.
)
Over 10% not
recommended
CAUTION!
Do not test the Humidity Sensor with an ohm meter or apply
any DC voltage.
This will render the Humidity Sensor defective.