- 45 -
5.5
Sensor
This option is used to calibrate the selected sensor. We recommend calibrate the sensor
before printing when changing the media.
Item
Description
Default
Auto
Calibration
This option is used to set the media sensor type and calibrate
the selected sensor automatically. Printer will feed 2 to 3 gap
labels to calibrate the sensor sensitivity automatically.
N/A
Manual setup
In case “Automatic” cannot apply to the media, please use
“Manual” function to set the paper length and gap/bline size
then scan the backing/mark to calibrate the sensor sensitivity.
N/A
Threshold
Detect
This option is used to set sensor sensitivity in fixed or auto.
Auto
Maximum
Length
This option is used to set the maximum length for label
calibration.
254
mm
Advanced
This function can set the minimum paper length and maximum
gap/bline length for auto-calibrate the sensor sensitivity.
N/A
Menu
Sensor
Auto Calibration
Gap
Black Mark
Continuous
Manual Setup
Gap
Black Mark
Continuous
Threshold Detect
Auto
Fixed
Maximum Length
Advanced