Configuration
GB
7.4
Teach-off of the room control unit from a heating zone
1. Choose the channel through which the room control unit shall be taught-off, by a short press of the
Select key (B). Pressing 1x = HZ1 / Pressing 2x = HZ2.... Pressing 10x = HZ10
2. Press the System key (A) and the Select key (B) simultaneously until the LED of the system key (A)
of the base station lights up in green.
If the room control unit is logged on to several Altech V3 IP base stations, this process must be
repeated for every base station.
3. Resetting the room control unit to factory settings (see manual of the respective room control unit).
7.5
Teach-in with Altech V3 IP Access Point
For a control via the IP app, the teach-on of the Altech V3 IP base station must be performed via the
Access Point (HAP 21001). Teach-in the device as follows:
Ö
The Altech V3 IP Access Point has been set-up via the IP app (see manual HAP 21001).
1. Open the IP app on your smart phone.
2. Select the menu item
Teach-in device.
3. Press the System key (A) shortly until the LED flashes slowly in orange. The teach-in mode is active
for three minutes.
4. The device will be displayed automatically in the IP app.
5. For confirmation, enter the last four digits of the device number (SGTIN) or scan the supplied QR
code. The device number can be found below the supplied QR code or directly on the device.
The LED will light up in green after a successful teach-in process. The process must be repeat-
ed if the LED lights up in red.
6. Follow the directions of the app.
8 Configuration
The Altech V3 IP base station is configured via the Altech V3 IP room control unit Display, Display S, or
via the Altech V3 IP Access Point in conjunction with the IP app.
8.1
Configuration with Altech V3 IP room control unit Display (S)
Proceed as follows in order to configure the Altech V3 IP base station via the Altech V3 IP room control
unit Display (S):
1. Press and hold the setting wheel (E) in order to open the configuration menu.
2. Select the symbol ”
“ and confirm the selection by shortly pressing the wheel.
If the room control unit is taught-in to more than one base station, select the desired base
station with the setting wheel.
The configuration menu for the Altech V3 IP base station includes device parameters “UnP1/UnP2” and
channel parameters “ChAn”, allowing to change lead and follow-up times for the pump, setback temper-
atures, time intervals and many other parameters. The following table shows the available parameters: