NO
FI
SE
FR
GB
DK
70
Configuration
GB
Parameters
Index
Value
Meaning
Time interval for valve
protection function:
P051
224
225
...
238 (default)
...
251
252
0 days
1 day
...
14 days
...
27 days
28 days
ChAn:
Parameters
Index
Value
Meaning
Pump lead time
(only available for
Ch01)
P006
128
129
130 (default)
...
147
148
0 minutes
1 minute
2 minutes
...
19 minutes
20 minutes
Duration of pump
protection function
(only available for
Ch01)
P007
128
129 (default)
...
137
138
0 minutes
1 minute
...
9 minutes
10 minutes
Pump follow-up time
(only available for
Ch01)
P008
128
129
130 (default)
...
147
148
0 minutes
1 minute
2 minutes
...
19 minutes
20 minutes
Minimum floor tem-
perature in connection
with a floor tempera-
ture sensor
P045
10
11
...
38 (default)
...
59
60
5.0 °C
5.5 °C
...
19.0 °C
...
29.5°C
30.0°C
Humidity limit
P050
40
…
80
168
…
188 (default)
…
208
40 %; inactive
…
80 %; inactive
40 %; active
…
60 %; active
…
80 %; active
Time interval for pump
protection function
(only available for
Ch01)
P051
225
226
...
238 (default)
...
251
252
1 day
2 days
...
14 days
...
27 days
28 days