Error Handling
9
2015.11.02
UG-01145_avmm_dma
Subscribe
Send Feedback
Each PCI Express compliant device must implement a basic level of error management and can optionally
implement advanced error management. The IP core implements both basic and advanced error
reporting. Error handling for a Root Port is more complex than that of an Endpoint.
Table 9-1: Error Classification
The
PCI Express Base Specification
defines three types of errors, outlined in the following table.
Type
Responsible Agent
Description
Correctable
Hardware
While correctable errors may affect system performance,
data integrity is maintained.
Uncorrectable, non-fatal Device software
Uncorrectable, non-fatal errors are defined as errors in
which data is lost, but system integrity is maintained.
For example, the fabric may lose a particular TLP, but it
still works without problems.
Uncorrectable, fatal
System software
Errors generated by a loss of data and system failure are
considered uncorrectable and fatal. Software must
determine how to handle such errors: whether to reset
the link or implement other means to minimize the
problem.
Related Information
PCI Express Base Specification 3.0
©
2015 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, ENPIRION, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words and logos are
trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other words and logos identified as
trademarks or service marks are the property of their respective holders as described at
www.altera.com/common/legal.html
. Altera warrants performance
of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any
products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information,
product, or service described herein except as expressly agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device
specifications before relying on any published information and before placing orders for products or services.
ISO
9001:2008
Registered
www.altera.com
101 Innovation Drive, San Jose, CA 95134