gasket that is furnished with the burner is placed
between the Gange of the Wood Gun™ and the
mounting Gange of the oil burner to prevent air
leakage.
E180, E250 Oil Burner
Oil/Gas Burner Combustion Chamber:
Models E100 and E140
Wood Gun™ models E100 and E140 have an
optional oil burner combustion chamber, which is
exterior to the boiler and located on the right hand
side of the boiler when viewed from the front. To
mount the combustion chamber, apply the enclosed
piece of 1/8 in x 1/2 in self-stick silicone strip to the
combustion chamber Gange just inside of the bolt
holes. A7ach the combustion chamber to the Gange
on the boiler using three 5/16 in x 1 in bolts and
washers.
e metal jacket cover and insulation on
the combustion chamber must be removed to gain
access to the holes in the Gange as shown below.
E100, E140 Combustion Chamber
A9er securing the combustion chamber to the
boiler, replace the insulated jacket.
e burner
mounting Gange should be bolted to the end of the
combustion chamber using four 3/8 in x 1 in bolts.
e burner should be positioned so that the end of
the air tube is back approximately ¼ in from the
inside of the ceramic lined chamber (see Figure 10)
Oil Burner Electrical Connection
Connect the burner in accordance with wiring
diagrams found in Appendix B: Wiring Diagrams.
e (T) terminals on the protector relay of the oil
burner may need to be crossed with a jumper wire to
activate the burner on certain models.
e Aux
(auxiliary) wire may not need to be terminated.
Oil Burner Fuel Line Connection
e fuel lines should be connected using copper
Gare 7ings or threaded pipe.
Oil Burner Adjustment
For proper oil burner adjustment, refer to the
burner installation manual.
Designing a multi-fuel boiler to burn both wood
and oil/gas e<ciently presents several problems not
normally associated with a conventional oil or gas
boiler. Wood combustion produces ash, which has a
tendency to accumulate on all exposed heat
exchange surfaces. Another signi cant factor is the
presence of water, which must be evaporated from
the fuel and carried out of the boiler in the exhaust
gas stream. In addition, products of incomplete wood
- 16 -
Never use compression fittings to
connect the fuel lines, since they
have a tendency to vibrate loose
during operation.
Note: If the oil tank has a two-pipe system, then it
is necessary to insert the bypass plug into the
burner pump as described in the manual for the
oil burner. When using a Riello Burner, always
use a two-pipe fuel line system.
Summary of Contents for wood gun E100 SF
Page 2: ......
Page 24: ...Photo Smoke flap installed 19 ...
Page 46: ...Steel Center Brick 8 Inch 41 ...
Page 49: ...Appendix A Boiler Specification Diagram 44 ...
Page 50: ... 45 ...
Page 51: ... 46 ...
Page 53: ...Appendix B Wiring Diagrams 48 ...
Page 54: ... 49 ...
Page 55: ... 50 ...
Page 56: ... 51 ...
Page 57: ... 52 ...
Page 58: ... 53 ...
Page 59: ... 54 ...
Page 60: ... 55 ...
Page 61: ...Appendix C Exploded Parts Drawings 56 ...
Page 63: ... 58 ...
Page 68: ...Appendix F Boiler Piping and Ducting Examples 63 ...