Page 5
7 Connections
(See Above)
7.1 Initial hookup procedure
After having properly secured the Surefire 512 to its mounting surface,
follow the procedure below to connect the unit to the stove / heater and to
the battery.
Step 1
Turn the on/off rocker switch to the off position.
Step 2
Connect the battery cables to the battery. The red cable must be connected to
the positive (+) terminal of the battery. The black cable must be connected to
the negative (-) terminal of the battery. Do not reverse! A reverse connection
will cause fuses (factory replaceable only) inside the unit to blow and possibly
cause other damage. A reversal also voids your warranty.
Step 3
Connect the stove / heater to the Surefire 512 by plugging the input ac
power cord of the stove / heater into the AC outlet of the Surefire 512.
Step 4
Plug the AC input power cord of the Surefire 512 into an ordinary 120 VAC
wall outlet. If the wall outlet is controlled by a switch then the switch should
be turned on.
Step 5
Turn the on/off rocker switch of the Surefire 512 to the "on" position unless
it is summer time and the stove is not in use.