background image

ATEX Product Instructions

1

The power source feeding the apparatus shall be an ATEX/IECEx approved barrier only

2

3

4
5

6

7

8
9

10

      Additional Notes

Installation shall be carried out in accordance with the applicable code of practice by suitably-trained personnel

.

If the equipment is likely to come into contact with aggressive substances, then it is the responsibility of the 
user to take suitable precautions that prevent it from being adversely affected, thus ensuring that the type 
of protection is not compromised.

For products other than PR3200 and PR3202 there are no special checking or maintenance conditions 
other than a periodic check. These products which may have aluminium enclosures (powder coated) 
should be located where friction sparks with steel objects are avoided. They should also be regularly 
inspected to ensure the coating is not damaged

A   A copy of certification marking as detailed on drawing number 8727.
B   A copy of the EC type examination certificates TRAC12ATEX0060X V2, IECEXTRC12.0025X issue 01.
C   Diagrams that may be necessary for safety, putting into service, maintenance, inspection etc.
D   Where applicable, the address of the importer or repairer will be specified.
E   On being put into service, the equipment will be accompanied by a translation of the instructions in the 
language
or languages of the country in which the equipment is to be used and by the instructions in the original language.
F   In addition to the wording normally applied (e.g. Clean Only With A Damp Cloth) the wording of the label shall

include the words ‘Warning: Danger of propagating brush discharge’ followed by the warning symbol ISO3864 No.

B.3.1 (black exclamation mark in black triangle, meaning: Caution, refer to accompanying documents). The

manufacturer’s instructions shall include details of the ignition hazard caused by propagating brush discharges and

the precautions to be taken to avoid the build up of static charge. (See note 6 above)

  Aggressive substances

 -  

  Suitable precautions

 -  

e.g. acidic liquids or gases that may attack metals or solvents that

 

may

affect polymeric materials.

e.g. regular checks as part of routine inspections or establishing from
the material's data sheet that it is resistant to specific chemicals

For the maximum cable lengths stated the cable capacitance shall not exceed 200pF/m otherwise the 
overall capacitance of Ci plus the cable capacitance shall not exceed 83nF
The equipment may be used with flammable gases, vapours and dust with apparatus group IIC and with 
temperature class T4. The apparatus is not permitted for use with dusts that have a layer smouldering 
temperature of 135oC or less.
The equipment may be used above surface Group II and Group III and in mining zone  Group I.
The equipment is only certified for use in ambient temperatures in the range -20oC to +70 oC and should 
not be used outside this range.
Propagating brush discharges are caused by non-conducting fluid flow over a non-conducting plastic 
surface. The product shall not be installed in areas where a high fluid flow may occur (for example in the 
case of a ruptured process pipe or compressed air pipe).
All repairs are to be carried out by 

Althen.

12

Protran® PR3850

 

User Manual

Summary of Contents for Protran PR3850

Page 1: ...e 2 65779 Kelkheim Germany Phone 49 0 6195 7 00 60 Fax 49 0 6195 70 06 66 Email info althen de www althensensors com Safety Maintenance General Information Product Instructions ATEX Product Instructions Dimensions 15 Version Disclaimer 11 13 Vers 22 6 Eng Protran PR3850 User Manual ...

Page 2: ... Intended Use 4 Safety 5 Maintenance and Care 6 Troubleshooting 7 Recycling 7 Product Instructions 8 Connections and Tightening Torques 9 ATEX Product Instructions 11 Technical Specifications 14 Version Information 15 Disclaimer 15 Contents Page Dimensions 13 Protran PR3850 User Manual ...

Page 3: ...ical specifications For options not listed please contact info althen de for support These operating instructions describe the safe and efficient handling and operation of the pressure transmitter or transducer and must be carefully read and understood prior to use Compliance with the specifications regarding safety and operation contained in these instructions is a prerequisite for safe operation...

Page 4: ... account the environmental conditions such as temperature humidity and atmospheric pressure etc Should be handled by qualified technical personnel only Limitation of Liability The manufacturer is not liable for damage resulting from non observance of these operating instructions Safety symbols The explanations of the symbols used in these operating instructions are listed below Type and Source of ...

Page 5: ...ARD HAZARD NOTICE Handling with Hydrogen NOT for use with Hydrogen Selection of personnel Only authorised and qualified personnel who have had experience and knowledge of the country specific regulations as well as the applicable standards and directives may be used for installation and operation Installation and commissioning must be carried out in accordance with these operating instructions The...

Page 6: ...cer for damage when unpacking If the pressure transmitter is damaged contact the manufacturer or your local dealer immediately WARNING Improper storage Improper storage of the pressure transducer may result in damage or malfunction of the product WARNING Ambient conditions during storage Temperature 5 C to 40 C Store in dry conditions System may be under pressure Loose parts and escaping media may...

Page 7: ...Adhere to temperature range Replace transmitter Clean pressure inlet hole Signal span outside of specification Output signal fluctuates noises EMC interference sources outside the specification Operating outside of temperature Measuring cell damaged e g by overpressure Pressure connection hole blocked Zero point signal outside of specification Measuring cell damage Operating outside of temperature...

Page 8: ...ogy Ensure electrical connector and cable gland are securely fitted and sealed MAINTENANCE Recalibration interval depends on own industry guidelines Do not insert pointed or hard objects in to the pressure port Repairs must be performed by manufacturer only REMOVAL END OF LIFE Ensure system is depressurised before removal Remaining media in pressure port may be hazardous Ensure system is not press...

Page 9: ...nnections and Tightening Torques PR3850 SERIES Process Connection Sealing Method Counter Part Weld Socket Part No 8016 Part No Z0093 O Ring Sensitive Membrane handle with care 9 Protran PR3850 User Manual ...

Page 10: ...rication coating and surface treatment If in doubt the manufacturer is to be consulted It is recommended that the PR3850 is used in conjunction with weld socket part No 8016 for best results Alternatively customer may machine an appropriate mating connection in their equipment to replicate the dimensions detailed in part 8016 detailed diagrams available on request Materials for mating part should ...

Page 11: ...e permanently fixed to the housing WARNING POTENTIAL ELECTROSTATIC CHARGING HAZARD DUE TO PROPOGATING BRUSH DISCHARGE SEE INSTRUCTIONS ATEX Product Instructions Specified to hazardous area installations Reference European ATEX Directive 2014 34 EU Annex II 1 0 6 The following instructions apply to equipment covered by certificate numbers TRAC12ATEX0060X V2 IECEXTRC12 0025X issue 01 The wording and...

Page 12: ...Damp Cloth the wording of the label shall include the words Warning Danger of propagating brush discharge followed by the warning symbol ISO3864 No B 3 1 black exclamation mark in black triangle meaning Caution refer to accompanying documents The manufacturer s instructions shall include details of the ignition hazard caused by propagating brush discharges and the precautions to be taken to avoid ...

Page 13: ...ase Notes 1 Item is shown for pictorial purpose only to define citical dimensions 2 Construction shall be in accordance with specification information 3 Label will show product name range and output signal Pin No 1 2 3 2 wire supply 4 20mA sig N C to case ELECTRICAL CONNECTION Vdc 13 Protran PR3850 User Manual ...

Page 14: ...mbient and Media 20 C to 85 C 4 F to 185 F 1 0 FS at room temperature 5 FS approx adjustment with easy access trimming potentiometers on amplified versions only Overpressure Safety PR3850 other options available Mating socket EN175301 803 Form A ex DIN43650 rated IP65 with PG9 cable entry Net Weight Kg 0 3 Kg Electrical Connection Response time 10 90 10 mS Wetted Parts SAE 316L stainless steel Pre...

Page 15: ...risk Althen will not be liable for any losses and or damages incurred from inproper use of equipment Althen operated a policy of continuous product development We reserve the right to change specification without prior notice All products manufactured by Althen are calibrated using precision calibration equipment traceable to national measurement standards Information provided within this manual i...

Reviews: