background image

Universal Quick Install Guide
Quantum and Triton Boards

Use this guide to install Quantum boards and Triton class telephony boards, 
including Triton VoIP, Triton Analog Extension, Triton Analog Trunk (LS and LS/
GS), Triton Resource, Triton T1/PRI, and Triton T1/E1 PRI, which are all different 
boards with common installation procedures.

All Triton PCI Family and Quantum Boards

Note:

In systems with over 12 boards installed, use the 10-connector side of the 
ribbon cable on the short end and use the 12-connector side of the ribbon 
cable on the long end. Starting with the innermost connectors, connect the 
boards, leaving a minimum of 3 connectors hanging off each end. 

Supported Board/Software Guidelines

Board

OE 

4.0A

OE 

4.0i

OE
4.5

OE/ACC/
ACM/HPBX 
4.6

OE/ACC/
ACM 5.0/
5.0A

OE/ACC/ACM/
HPBX 5.0A 
Update 2 & 3

OE/ACC/ACM/
HPBX 5.0A 
Update 4 & up

Quantum

Yes

No

Yes

Yes

Yes

Yes

Yes

Triton Analog Extension

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Triton Analog Extension B

No

No

No

No

No

No

Yes

Triton Analog Trunk-12

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Triton Analog Trunk-8

No

No

No

No

No

Yes

Yes

Triton T1/PRI

Yes

No

Yes

Yes

Yes

Yes

Yes

Triton T1/E1 PRI

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Triton VoIP-30

No

No

Yes

Yes

Yes

Yes

Yes

Triton VoIP-8

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Triton Resource

Yes

Yes

Yes

Yes

Yes

Yes

Yes

MVIP BUS Termination Switch

Board Silhouette

Power Cable

MVIP Connector

Summary of Contents for Quantum Boards

Page 1: ...t connectors connect the boards leaving a minimum of 3 connectors hanging off each end Supported Board Software Guidelines Board OE 4 0A OE 4 0i OE 4 5 OE ACC ACM HPBX 4 6 OE ACC ACM 5 0 5 0A OE ACC ACM HPBX 5 0A Update 2 3 OE ACC ACM HPBX 5 0A Update 4 up Quantum Yes No Yes Yes Yes Yes Yes Triton Analog Extension Yes Yes Yes Yes Yes Yes Yes Triton Analog Extension B No No No No No No Yes Triton A...

Page 2: ...eference Ensure that your system is not referenced to the T1 or T1 E1 PRI board that is not connected to the CO This may require changing the MVIP clock setting from automatic to manual and selecting the board number connected to the CO currently in service Triton Analog Only The audio input and first extension share the same physical port The first extension port cannot be used as a physical exte...

Page 3: ...re are 3 connection options for connecting Quantum Triton boards to trunks and extensions 1 12 Ports Bridging Adapter 2 66 Punch Down Block with 50 Pin Telco Female Connector 3 Patch Panel with 50 Pin Telco Female Connector ...

Page 4: ...D on the back of each board Each board has its own set of board IDs It is recommended that you assign each board a unique ID Quantum 0 F ID 0 cannot be used in Windows 2000 server Triton T1 PRI 0 7 only 0 5 is supported in OE 4 5 or above Triton T1 E1 PRI 0 7 only 0 5 is supported in OE 4 5 or above Triton Resource 0 1 Triton VoIP 0 A Triton Analog Extension 12 extensions 0 F Triton Analog Trunk 0...

Page 5: ...ails note the failing board and replace it Repeat installation procedures starting from Step 1 Before returning the defective board contact AltiGen for an RMA number 14 If the board s have been properly installed the newly installed boards will appear in the Boards View window in AltiWare Administrator Installing Channel Service Unit CSU to the Triton T1 or T1 E1 PRI Board 1 Connect the CSU Adtran...

Page 6: ..._________________ End User Name ____________________________________________________ Location __________________________________________________________ Credit Card if required __________________________ Expiration___________ Serial ____________________________________________________ AltiWare Release _______________ Chassis Type____________________BTOS________________ Number of AltiGen boards ins...

Reviews: