7. Operation 

The CP452 is designed for use in a fixed application where the system 
boots up directly into the user application and does not allow access to the 
operating system.  The application and GUI interface are normally created 
using a standard desktop computer and then installed onto the CP452 using 
a USB drive or network connection. 

Once set-up, the CP452 will work trouble free without user intervention.    

7.1 Power Up and Shutdown 

The CP452 boots automatically as soon as power is applied. There is no 
need to press the power switch on the bottom of the unit.  In most 
installations, the system boots directly into the end-user application. 

The CP452 can be powered down using the shutdown/power off option 
from the START menu, or directly from an AVSnap application using the 
"App.Shutdown" function. 

7.2 Preparing Control Software 

It is not recommended to design and create control software directly on 
the CP452. In most situations, it is easier and faster to write and debug 
control software on a standard desktop computer and then transfer the 
completed file when ready. However, if the CP452 needs to be 
programmed "in place", use an external USB keyboard and mouse. Simply 
plug in the devices and wait for the system to recognize the new hardware 
and load the drivers. 

Remember, the CP452 employs the Enhanced Write Filter (EWF) to 
protect the contents of the internal drive. Read the next section carefully 
before attempting to install, create, or edit any data files or applications on 
the CP452. If not executed properly, changes will be lost. 

The best way to create and edit on the CP452 is to use a USB drive plugged 
into the bottom of the unit and make changes directly to the USB drive 
then copy the final files to the CP452’s "C" drive. 

7.3 Installing Files and Applications 

The CP452 utilizes the Windows XP Embedded EWF to protect the 
CP452’s internal memory from accidental or unauthorized changes. The 
EWF appears to read and write from the internal drive, but executes 
everything in RAM. All changes WILL be lost after reset or shutdown 
unless the changes are committed to memory. Three batch files are 
provided for direct control over the EWF and should be used cautiously. 

1. COMMIT.BAT – Write to hard drive 

This batch file resides on the desktop and writes the RAM data onto 
the hard drive for permanent storage while EWF is enabled.  Close 
open applications before running this batch file or the changes may 
not be committed to memory. 

2. ENABLE.BAT – Turn on EWF 

This batch file resides in the root directory and turns on the EWF. In 
this mode, no changes made to the system are saved unless the 
COMMIT batch file is executed. This is the default condition for all 
CP452s.  

3. DISABLE.BAT – Turn off EWF 

This batch file resides in the root directory and turns off the EWF. In 
this mode, the system operates like a normal computer reading and 
writing data directly to the hard drive.  

WARNING 

When the EWF is turned off, the user MUST shutdown the computer 
properly. If power is turned off or lost without executing the normal 
shutdown  procedure,  data  can  be  lost,  or  corrupted,  including  the 
BIOS and operating system (OS). If the BIOS or OS are damaged, the 
entire system can become unusable.  

7.3.1 Installing Large Files 

If the application or file is too large for the available RAM, the operation 
will be aborted. Use the disable batch file before installing the software.  
Make sure to reset the EWF when done. 

 
 

Summary of Contents for CP452-009 MultiTouch

Page 1: ...led and used in accordance with the instructions found herein may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interf...

Page 2: ...aluminum AC407 101 Black Bezel aluminum AC407 102 Silver Bezel aluminum AC407 103 50 ft Power Extension CB142 050 Table 1 CP452 009 General Does not apply to wall installations Mechanical CP452 009 M...

Page 3: ...to the LAN using standard network cable AVSnap or other RS 232 communication software can then be used to control the serial device using the IP address of the adapter in place of the COM port In thi...

Page 4: ...CP45 CP45 CP45 CP452 2 2 2 009 009 009 009 User s Guide 400 0546 001 4 6 Application Diagrams Diagram 1 Typical Setup...

Page 5: ...CP45 CP45 CP45 CP452 2 2 2 009 009 009 009 User s Guide 400 0546 001 5 Diagram 2 Dimensions 10 5 267 mm 6 2 157 mm 1 5 38 mm 2 1 53 mm 8 3 210 mm 4 6 117 mm 6 2 157 mm 1 5 38 mm...

Page 6: ...CP45 CP45 CP45 CP452 2 2 2 009 009 009 009 User s Guide 400 0546 001 6 Diagram 3 Bezel Dimensions 11 2 284 mm 6 5 164 mm 0 3 6 mm...

Page 7: ...te and edit on the CP452 is to use a USB drive plugged into the bottom of the unit and make changes directly to the USB drive then copy the final files to the CP452 s C drive 7 3 Installing Files and...

Page 8: ...there is AC power to the adapter and the panel still does not turn on the CP452 or the power adapter may require service call ALTINEX at 714 990 2300 Software Files Are Missing 1 Always make changes t...

Reviews: