MN-29758 (Rev. 6) 05/15 •
TH/III-SK/III Series Cook, Hold, Smoke •
29
s e r V I c e
d a n g e r
Disconnect unit from power source
before cleaning or servicing. Failure
to observe this precaution can cause
electrical shock and personal injury.
n o t e
If the appliance has been unplugged for an
extended period of time, the Real Time Clock
may require recharging. Turn main breaker to the
unit off for 10 seconds and then restore power.
For more information, see Error Code E-60 in the
Troubleshooting section of this manual.
c a U t I o n
This section is provided for the assistance
of qualified and trained service technicians
only and is not intended for use by untrained
or unauthorized service personnel. Failure to
observe this precaution may void the warranty.
a. no power. display will not light.
1. Verify that power is available at the outlet or junction box.
2. Verify that the circuit breaker switch on the back of the unit is turned on.
3. Verify that the power cord is not open. Check continuity with a VOM meter.
4. If the problem persists, call a qualified Alto-Shaam service technician at 1-800-558-8744.
B. display is lit but unit is not heating.
Check to verify that the high limit switch located at the rear of the unit top has not been
tripped. If it has been tripped, reset by pressing in the hi-limit reset button at the rear
of the oven.
After resetting, the cause of the high limit trip must be corrected. If the high limit switch
will not reset, the high limit switch is defective and must be replaced.
This is a safety
device and must not be bypassed or removed from the circuit.
C. To test air sensor:
Test air sensor by placing sensor in ice water bath and using an ohmmeter set on the ohm scale.
The reading should be 100 ohms resistance. If it is more than 2 ohms higher or lower, sensor
needs to be replaced.
d. to test probe sensor:
Test food probe by placing in ice water bath and using an ohmmeter set on the ohm scale.
The reading should be 100 ohms resistance.
troUBle shootIng Internal electrIcal coMponents
d a n g e r
Lock-out or post breaker panel
until service work until service
work has been completed.
This section is provided for the assistance of qualified technicians only and is not intended for use by untrained
or unauthorized service personnel.
If your Alto-Shaam
®
unit is not operating properly, check the following before
calling your Authorized Alto-Shaam Service Agent:
☛
Check main power circuit breaker to the unit and verify that the circuit breaker on the back of the unit is turned
on, if applicable.
Do not attempt to repair or service the unit beyond this point. Contact Alto-Shaam for the nearest authorized
service agent. Repairs made by any other service agents without prior authorization by Alto-Shaam
®
will
void the warranty on the unit.
Summary of Contents for 1000-SK/III
Page 47: ...MN 29758 Rev 6 05 15 TH III SK III Series Cook Hold Smoke 45 ...
Page 48: ...MN 29758 Rev 6 05 15 TH III SK III Series Cook Hold Smoke 46 ...
Page 49: ...MN 29758 Rev 6 05 15 TH III SK III Series Cook Hold Smoke 47 ...
Page 50: ...MN 29758 Rev 6 05 15 TH III SK III Series Cook Hold Smoke 48 ...
Page 51: ...MN 29758 Rev 6 05 15 TH III SK III Series Cook Hold Smoke 49 ...
Page 52: ...MN 29758 Rev 6 05 15 TH III SK III Series Cook Hold Smoke 50 ...
Page 53: ...MN 29758 Rev 6 05 15 TH III SK III Series Cook Hold Smoke 51 ...
Page 54: ...MN 29758 Rev 6 05 15 TH III SK III Series Cook Hold Smoke 52 ...
Page 55: ...MN 29758 Rev 6 05 15 TH III SK III Series Cook Hold Smoke 53 ...
Page 56: ...MN 29758 Rev 6 05 15 TH III SK III Series Cook Hold Smoke 54 ...
Page 57: ...MN 29758 Rev 6 05 15 TH III SK III Series Cook Hold Smoke 55 ...
Page 58: ...MN 29758 Rev 6 05 15 TH III SK III Series Cook Hold Smoke 56 ...