8.
6•10
es
31-3/8" (796mm)
34-1/16" (864mm)
17-15/16"
(456mm)
7-9/16"
(191mm)
WATER
DRAIN
33-1/8" (840mm)
4-15/16"
(125mm)
Steam
Ve
nt (T
op)
60-9/16" (1538mm)
Water Drain
(Back)
Treated Water
Intake (Bottom)
Untreated Water
Intake (Bottom)
Electrical Connection
(Bottom)
30" (761mm)
3-3/4" (95mm)
2-3/16" (56mm)
(283m
m)
6-3/8" (161mm)
41-15/16" (1064mm)
43-7/8" (1114mm)
2" (50mm)
49-1/8" (1247mm)
15-7/8"
(403mm)
13-1/2"
(343mm)
35-3/16" (893mm)
26-1/2"
(673mm)
7-9/16"
(192mm)
11-1/8"
weight
capacity
neT
285 lb
(129 kg)
Full-siZe pans: 20" x 12" x 2-1/2"
six (6)
ship
465 lb
(211 kg)
gn 1/1:
gn 2/1:
530 x 325 x 65mm
650 x 530 x 65mm
six (6)
Three (3)
craTe diMensions: (l x w x h)
53" x 45" x 49"
(1346 x 1143 x 1245mm)
halF-siZe sheeT pans:*
18" x 13" x 1"
six (6)
on wire shelVes only
72 lb (33 kg) MaXiMuM
VoluMe MaXiMuM: 45 quarts (57 liters)
installation requirements
• Oven must be installed level. • Hood installation is required.
• Water supply shut-off valve and back-flow preventer when required by local code.
electrical
(DEDICATED CIRCUIT REQUIRED)
Model
VolTage
ph
hZ
aMps
kw
awg
cord & plug
6•10ES Touch
208 – 240
1*
60
44.0 - 50.0
9.1 - 12.0
awg 6
no cord or plug
208 – 240
3
60
25.2 - 28.4/ph
9.1 - 11.7
awg 8
no cord or plug
380 – 415
3
50
14.0 - 16.3/ph
9.0 - 11.7
awg 12
no cord or plug
6•10ES
208 – 240
1*
60
40.8 - 47.0
8.5 - 11.2
awg 6
no cord or plug
208 – 240
3
60
23.5 - 27.0/ph
8.5 - 11.2
awg 8
no cord or plug
380 – 415
3
50
13.0 - 16.0/ph
8.5 - 11.2
awg 12
no cord or plug
*elecTrical serVice charge applies
water requirements
water quality minimum standards
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" npT*
ONE (1) UNTREATED WATER INLET: 3/4" npT*
LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar
WATER DRAIN: 1-1/2" connecTion wiTh a 2" MiniMuM air
gap insTalled as close To The oVen as possiBle
using a waTer supply noT MeeTing alTo-shaaM’s MiniMuM
waTer QualiTy sTandards will Void This warranTy.
it is the responsibility of the purchaser to ensure that incoming water supply is
compliant with the specifi cations listed through adequate treatment measures.
installation of the combiguard
TM
water Filtration system is recommended, but
this system may not address all water quality issues present.
clearance requirements
Contaminant
Free chlorine
hardness
chloride
ph
alkalinity
silica
Total dissolved solids (tds)
Inlet Water Requirements (
untreated water
)
less than 0.1 ppm (mg/l)
less than 3 gpg (52 ppm)
less than 30 ppm (mg/l)
7.0 to 8.5
less than 50 ppm (mg/l)
less than 12 ppm (mg/l)
less than 60 ppm
LEFT 6" (152mm)
RECOMMENDED SERVICE ACCESS: 18" (457mm)
20" (508mm)
FROM HEAT PRODUCING EQUIPMENT
RIGHT 4" (102mm) TOP: 20" (508mm)
For air MoVeMenT
BACK 4" (102mm) BOTTOM: 5-1/8" (130mm)
For legs
counTer-Top insTallaTions MusT MainTain
4" (102mm)
MiniMuM
clearance FroM counTer surFace
* can manifold off of
one 3/4" line.
dimensions:
h x w x d
EXTERIOR:
35-3/16" x 43-7/8" x 34-1/16" (893mm x 1114mm x 864mm)
EXTERIOR WITH RECESSED DOOR:
35-3/16" x 47-7/8" x 34-1/16" (893mm x 1216mm x 864mm)
INTERIOR:
17-3/4" x 23-1/2" x 21-1/16" (450mm x 597mm x 535mm)
stacking combination dimensions:
h x w x d
6.10es over 6.10es
66-3/4" x 44" x 36-5/8" (1693 x 1115 x 930mm)
6.10es over 10.10es
73-1/8" x 44" x 36-5/8" (1857 x 1115 x 930mm)
6.10es over 7.14es
67" x 44" x 43" (1701 x 1115 x 1090mm)
6.10es over 10.18es
72-3/4" x 44" x 43" (1845 x 1115 x 1090mm)
Mobile option with 5" (127mm) casters will add 2" (51mm) to the overall height
6.10es over asc-4e
74" x 44" x 44-1/2" (1878 x 1115 x 1130mm)