COMbIThERM® ES SERIES
•
ELECTRIC
INSTALLATION MANUAL #MN-28897 •
15.
7•14
es
i
TOP VIEW
FRONT VIEW
SIDE VIEW
Arial MT
Condensed Light
8 pt
43-3/4" (1111mm)
8-1/2" (216mm)
26-1/2" (672mm)
6-1/4" (159mm)
35-7/16" (899mm)
13"
(330mm)
15-3/4" (400mm)
22-5/8" (576mm)
3-3/4" (95mm)
2-5/16" (58mm)
weight
capacity
neT
405 lb
(184 kg)
Full-siZe pans: 20" x 12" x 2-1/2"
Fourteen (14)
ship
540 lb
(245 kg)
gn 1/1: 530 x 325 x 65mm
Fourteen (14)
craTe diMensions: (l x w x h)
gn 2/1: 650 x 530 x 65mm
seven (7)
53" x 45" x 49"
Full-siZe sheeT pans:*
18" x 26" x 1"
seven (7)
(1346 x 1143 x 1245mm)
on wire shelVes only
168 lb (76 kg) MaXiMuM
VoluMe MaXiMuM: 105 quarts (133 liters)
*addiTional wire shelVes reQuired For MaXiMuM capaciTy
installation requirements
• Oven must be installed level. • Hood installation is required.
• Water supply shut-off valve and back-flow preventer when required by local code.
electrical
(DEDICATED CIRCUIT REQUIRED)
combismoker
®
Model
VolTage
ph
hZ
aMps
kw
awg
cord & plug
additional kw
7•14ESi Touch
208 – 240
1*
60
70.0 - 79.2
14.5 - 19.0
awg 3
no cord or plug
+ .7 kw
208 – 240
3
60
40.3 - 46.0/ph
14.5 - 19.0
awg 6
no cord or plug
+ .7 kw
380 – 415
3
50
22.0 - 26.3/ph
14.4 - 18.9
awg 10
no cord or plug
+ .7 kw
440 – 480
3*
60
19.0 - 22.8/ph
14.4 - 19.0
awg 8
no cord or plug
+ .7 kw
7•14ESi
208 – 240
1*
60
69.2 - 79.0
14.4 - 18.9
awg 3
no cord or plug
+ .7 kw
208 – 240
3
60
40.0 - 45.5/ph
14.4 - 18.9
awg 6
no cord or plug
+ .7 kw
380 – 415
3
50
22.0 - 26.3/ph
14.4 - 18.9
awg 10
no cord or plug
+ .7 kw
440 – 480
3*
60
21.0 - 23.0/ph
15.9 - 18.9
awg 8
no cord or plug
+ .7 kw
*elecTrical serVice charge applies
water requirements
water quality minimum standards
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" npT*
ONE (1) UNTREATED WATER INLET: 3/4" npT*
LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar
WATER DRAIN: 1-1/2" connecTion wiTh a 2" MiniMuM air
gap insTalled as close To The oVen as possiBle
using a waTer supply noT MeeTing alTo-shaaM’s MiniMuM
waTer QualiTy sTandards will Void This warranTy.
it is the responsibility of the purchaser to ensure that incoming water supply is
compliant with the specifi cations listed through adequate treatment measures.
installation of the combiguard
TM
water Filtration system is recommended, but
this system may not address all water quality issues present.
clearance requirements
Contaminant
Free chlorine
hardness
chloride
ph
alkalinity
silica
Total dissolved solids (tds)
Inlet Water Requirements (
untreated water
)
less than 0.1 ppm (mg/l)
less than 3 gpg (52 ppm)
less than 30 ppm (mg/l)
7.0 to 8.5
less than 50 ppm (mg/l)
less than 12 ppm (mg/l)
less than 60 ppm
LEFT 6" (152mm)
RECOMMENDED SERVICE ACCESS: 18" (457mm)
20" (508mm)
FROM HEAT PRODUCING EQUIPMENT
RIGHT 4" (102mm) TOP: 20" (508mm)
For air MoVeMenT
BACK 4" (102mm) BOTTOM: 5-1/8" (130mm)
For legs
counTer-Top insTallaTions MusT MainTain
4" (102mm)
MiniMuM
clearance FroM counTer surFace
* can manifold off of
one 3/4" line.
dimensions:
h x w x d
EXTERIOR:
35-7/16" x 43-3/4" x 42-13/16" (899mm x 1111mm x 1087mm)
EXTERIOR WITH RECESSED DOOR:
35-7/16" x 47-3/4" x 42-13/16" (899mm x 1213mm x 1087mm)
INTERIOR:
20-5/16" x 23-1/2" x 28-7/8" (515mm x 596mm x 722mm)
stacking combination dimensions:
h x w x d
6.10es over 7.14es
67" x 43-7/8" x 42-15/16" (1701 x 1114 x 1090mm)
7.14es over 7.14es
67" x 43-7/8" x 45-1/4" (1701 x 1114 x 1150mm)
7.14es over asc-4e
73-5/8" x 41-7/8" x 46-9/16" (1869 x 1064 x 1182mm)
Mobile option with 5" (127mm) casters will add 2" (51mm) to the overall height.