Electrical usage
An identification tag is permanently mounted on the cabinet. Permanent wiring
or electrical outlets for this merchandiser must be installed by a licensed
electrician in accordance with local, country, or national codes.
This merchandiser must be connected to a dedicated circuit: (see below)
▪
HSM-48: 30 Amp circuit
▪
HSM-36: 20 Amp circuit
▪
HSM-24: 20 Amp circuit
Cord and plug models
▪
In the event of an emergency, always position the merchandiser so the power
supply cord is easily accessible.
▪
Plug the unit into a properly grounded receptacle only. Arcing will occur when
connecting or disconnecting the unit unless all controls are in the OFF position.
Hard wired model:
Hard wired models must be equipped with a country certified external allpole
disconnection switch with sufficient contact separation.
If a power cord is used for the connection of the product, an oil resistant cord like
H05RN or H07RN equivalent must be used.
NOTICE
Where local codes and CE regulatory requirements apply,
appliances must be connected to an electrical circuit that is
protected by an external GFCI outlet.
CAUTION
Power source must match the voltage identified on appliance
rating tag. The rating tag provides essential technical
information required for an appliance installation, maintenance
or repairs. Do not remove, damage or modify the rating tag.
WARNING
To prevent serious injury, death, or property damage:
All electrical connections must be made by qualified and trained
service technician in accordance with applicable electrical codes.
This appliance must be adequately grounded in accordance with
local electrical codes or, in the absence of local codes, with the
current edition of the National Electrical Code ANSI/NFPA No. 70.
In Canada, all electrical connections are to be made in
accordance with CSA C22.1, Canadian Electrical Code Part 1 or
local codes.
CE-approved appliances include an equipotential-bonding
terminal marked with the symbol shown on the left. Provisions
for earthing are to be made in accordance with IEC:2010 60335-1
section 27 or local codes.