An identification tag is permanently mounted on
the cabinet.
Permanent wiring or electrical outlets for this
appliance must be installed by a licensed electrician
in accordance with local, country, or national codes.
This appliance must be connected to a dedicated
circuit:
(see belo w )
HSM-38/3S –– 20 Amp circuit
HSM-48/5S –– 30 Amp circuit
Always position the appliance so the power supply
cord is easily accessible in case of emergency. Plug
the unit into a properly grounded receptacle ONLY.
Arcing will occur when connecting or disconnecting
the unit unless all controls are in the OFF position.
NOTE
: The appliance must be connected to an
electrical circuit that is protected by an
external GFCI outlet.
I N S T A L L A T I O N
E L E C T R I C A L
ELECTRICAL, HSM-48/5S
FIVE SHELF UNIT
VOLTAGE
PHASE CYCLE
/
HZ
AMPS
kW
CORD SUPPLIED
WITHOUT PLUG
208-240 1
50/60
24.0
5.7
NEMA
L6-30P
30A-250V
MUST BE ON ITS OWN
30
AMP CIRCUIT
RECOMMENDED
380
3
50/60
10.0
5.7
CORD SUPPLIED
NO PLUG
ELECTRICAL, HSM-48/3S
THREE SHELF UNIT
VOLTAGE PHASE CYCLE
/
HZ
AMPS
kW
CORD SUPPLIED
WITHOUT PLUG
208-240
1
50/60
12.5
3.0
NEMA
6-20P
20A-250V
MUST BE ON ITS OWN
20
AMP CIRCUIT
RECOMMENDED
230
1
50/60
11.75 2.7
CORD
,
NO PLUG
D A N G E R
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.