An identification tag is permanently mounted on
the unit.
Permanent wiring or electrical outlets for
this appliance must be installed by a licensed
electrician in accordance with local, country,
or national codes.
Always position the appliance so the power
supply cord is easily accessible in case of
emergency.
Plug the unit into a properly grounded receptacle
ONLY. Arcing will occur when connecting or
disconnecting the unit unless all controls are in
the OFF position.
For 230V units:
To prevent an electrical shock hazard between the
appliance and other appliances or metal parts in
close vicinity, an equalization-bonding stud is
provided. An equalization bonding lead must be
connected to this stud and the other appliances /
metal parts to provide sufficient protection against
potential difference. The terminal is marked with
the following symbol.
NOTE:
The appliance must be connected to an
electrical circuit that is protected by an
external GFCI outlet.
# 8 9 7 a • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 5.
I N S TA L L AT I O N
E l e c t r i c a l I n s t a l l a t i o n
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be made
in accordance with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.
ELECTRICAL
VOLTAGE PH CYCLE
/
HZ
AMPS
kW
230
1
50
6.0
1.4
BSI363/A
250V
PLUG