American-Lincoln Technology
1-31
ATS 46/53 Troubleshooting Guide
MAIN & SIDE BROOM CIRCUITS (BATTERY)
MAIN AND SIDE BROOM CIRCUITS
Conditions necessary for circuits to work
1.
Battery Voltage
2.
Key switch in on
3.
CB-6, CB-12 and CB-13 closed
4.
Hopper switch closed (HOPPER DOWN)
5.
Hopper door #2 switch closed (Hopper door full open)
6.
Main broom switch closed
7.
Side broom switch closed
8.
Solenoids (4A) and (5A) energized and contacts closed.
36 V BATTERY
0775-166
0775-166
MAIN
BRM. MTR.
SIDE
BRM. MTR.
16
17
4A
5A
(P)
19
CB-12
25 AMP.
CB-13
15 AMP.
+
-
+
MTR
MTR
54
18
BATT.
1
IGN
KEY SW.
3A
25
3, 3B, 3D
15 AMP.
CB-6
(C) (NO)
(C)
(NO)
37
HD-SW.
#2
36
HO-SW.
CLOSED WHEN HOPPER
IS FULL DOWN
ACC
CLOSED WHEN DOOR
IS FULL OPEN
CLOSED WHEN BROOM
LEAVES FULL UP POSITION
(NO) 39, 39A
22
40
4A
5A
(C)
(C)
MAIN
BRM. MTR.
SIDE
BRM. MTR.
(NC)
CLOSED, HELD OPEN WITH BROOM
IN FULL UP POSITION
MAIN BROOM SOL.
SIDE BROOM SOL.
39A
77B, C
77D, E
T124