1-36
American-Lincoln Technology
ATS 46/53 Troubleshooting Guide
HOPPER VACUUM CIRCUIT (BATTERY)
HOPPER VACUUM CIRCUIT
Conditions necessary for circuits to work
1.
Battery Voltage
2.
Key switch in on
3.
CB-1 and CB-6 closed
4.
Solenoid 3A closed
5.
M4 closed (De-energized)
6.
Hopper switch closed (Hopper Down)
7.
Hopper Door switch#2 closed (Hopper Door full open)
8.
Dust control switch closed
9.
Main Broom switch closed (Main Broom not in full up position)
+
-
0775-166
0775-166
(N)
(P)
-
+
VAC MTR.
MTR
CB-1
25 AMP
1
BATT.
1A, 1C
IGN
ACC
KEY SW.
3, 3B, 3D
22
21
87A
3A
20
FAN SOL.
(DUST CTRL.-SW.)
WSB-SW
M4
30
HD-SW.
#1
(NO)
(C)
(C)
36A
(NO)
36
(C)
HD-SW.
#2
CLOSED WHEN
DOOR IS FULL OPEN
CLOSED WHEN HOPPER
DOOR IS FULL DOWN
3A
15 AMP
CB-6
25
H0-SW.
MAIN
BRM. SW.
39, 39A
(NO)
CLOSED WITH BROOM
LEAVES FULL UP POSITION
37
(C)
T127