MK
EQU231TWIN
Rear Panel
-
II
EQU231VU
/EQU231
Rear Panel
MK
MK
-
II
-
II
14
20
19
17
16
15
MK
EQU215TWIN
Rear Panel
-
II
19
20
18
7
18
20
19
17
16
15
EQU131VU
Rear Panel
MK
-
II
19
20
18
15. XLR input and output connector
The XLR connector are actively balanced and are used to input/output the signal.
14.Power switch
This is used to switch the equalizer on and off. The appliance would be turned on when the power switch to be
set to the on-position, and it would be turned off when the switch be set to the off-position.
GND
LIFT
ON
OFF
POWER
SERIAL
MODEL
AC INPUT
95-120V
/210-240V
60-50Hz
Rated Power Consumption 9W
FUSE:
210-240V: T100mAL 250VAC
95-120V: T160mAL 250VAC
REPLACE FUSE WITH CORRECT
TYPE ONLY
Apparaten skall anslutas till
jordat uttag nar den ansluts
till ett natverk
BALANCED
UNBALANCED
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
OUTPUT
BALANCED
UNBALANCED
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
INPUT
CHANNEL 1
BALANCED
UNBALANCED
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
OUTPUT
BALANCED
UNBALANCED
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
INPUT
CHANNEL 2
PUSH
2
1
3
NEW
TIDE
PUSH
2
1
3
NEW
TIDE
17
16
15
17
16
15
GND
LIFT
ON
OFF
POWER
SERIAL
MODEL
AC INPUT
95-120V
/210-240V
60-50Hz
Rated Power Consumption 9W
FUSE:
210-240V: T100mAL 250VAC
95-120V: T160mAL 250VAC
REPLACE FUSE WITH CORRECT
TYPE ONLY
Apparaten skall anslutas till
jordat uttag nar den ansluts
till ett natverk
BALANCED
UNBALANCED
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
INPUT
BALANCED
UNBALANCED
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
OUTPUT
PUSH
2
1
3
NEW
TIDE
14
14
17
16
15
GND
LIFT
SERIAL
MODEL
ON
OFF
POWER
AC INPUT
95-120V
/210-240V
60-50Hz
Rated Power Consumption 18W
FUSE:
210-240V: T100mAL 250VAC
95-120V: T200mAL 250VAC
REPLACE FUSE WITH CORRECT
TYPE ONLY
Apparaten skall anslutas till
jordat uttag nar den ansluts
till ett natverk
BALANCED
UNBALANCED
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
INPUT
BALANCED
UNBALANCED
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
OUTPUT
BALANCED
UNBALANCED
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
INPUT
BALANCED
UNBALANCED
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
OUTPUT
CHANNEL 1
CHANNEL 2
PUSH
2
1
3
NEW
TIDE
18
PUSH
2
1
3
NEW
TIDE
17
16
15
ON
OFF
POWER
SERIAL
MODEL
AC INPUT
95-120V
/210-240V
60-50Hz
Rated Power Consumption 18W
FUSE:
210-240V: T100mAL 250VAC
95-120V: T200mAL 250VAC
REPLACE FUSE WITH CORRECT
TYPE ONLY
Apparaten skall anslutas till
jordat uttag nar den ansluts
till ett natverk
GND
LIFT
BALANCED
UNBALANCED
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
INPUT
BALANCED
UNBALANCED
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
OUTPUT
BALANCED
UNBALANCED
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
INPUT
BALANCED
UNBALANCED
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
OUTPUT
CHANNEL 1
CHANNEL 2
14
PUSH
2
1
3
NEW
TIDE
PUSH
2
1
3
NEW
TIDE
17
16
15
17
16
15