Test Procedures for
AlphaVerb
Amplitude response test
On PC:
-Load file:
alfaverb_amplitude ( APWin File menu / Open / Test )
Test Connections:
-
Output A of Audio Precision System Two --> LEFT input of the device under test.
-
LEFT output of the device under test --> A input of Audio Precision System Two
-
RIGHT output of the device under test --> B input of Audio Precision System Two
On the
Alphaverb
:
-Turn on the power switch.
-Set INPUT volume to maximum.
-Set OUTPUT volume to maximum.
-Set PROGRAM to
DELAY
.
-Set VARIATION to 1.
Start the sweep (F9) and control the results (Page3 – Graph) in the following conditions:
-MIX potentiometer turned to 0.
-MIX potentiometer turned to 10.
Audio Precision
05/22/02 12:55:43
alfaverb_amplitude.at2c