background image

Setting the current time

 

In the standby mode (the display is off), press the "<" or ">" button to enter 
the current time display menu, then press and hold the "<" button and then 
press the "P" button.
The display shows the current time and the custom symbol flashes.
Set the current time by pressing the "<" and ">" buttons.
The set time is stored in memory after pressing the "P" button.
Note: To quickly change the input values to the higher or lower side, press 
and hold the "<" or ">" button, respectively.

Adjusting the clock

In the current time display mode, you need to press the "<" or ">" button 
once to display the seconds, then press and hold the "<" or ">" button and 
press "P" in addition.
The display shows "C 00" - the value of the adjustment of the clock.
A positive number accelerates the clock, and a negative slows down.
One division (unit) is 1 second per day.
Set the desired value by pressing the "<" and ">" buttons.
The entered value is stored after pressing the "P" button.
Note: for example, if the clock rushes for 6 seconds per day, you must 
enter the value "-06".

Starting the heater

Manually: by pressing the direct switch    .
Using INPUT: using an external signal at the INPUT.
By timer: by presetting the on time.
After starting the 

car 

parking heater, the display shows "On:XX", where XX 

is the remaining operating time.
To change the remaining operation time, press and / or hold down the "<" 
or ">" button, the configurable symbol flashes.
To save the entered value, press the "P" button.
Note: When controlling an external signal with a constant level at the 
INPUT input or when the heater is automatically started in the "P2-
preheater" mode (described below), "On:--" is displayed.

Stop the heater 

Manually: by pressing the direct switch    .
Using INPUT: using an external signal at the INPUT.
Automatically: at the end of the heater operating time.
After turning the heater off, "OFF" is displayed.

Description of errors

If errors occur during the data exchange on the digital control bus (

E-Bus 

or W-Bus)

 of the

 car

 

parking 

heater, the device displays the text "Err.X", 

where X is the error number:

Err.A

 

Error in auto-detecting the type of digital heater (type A0) 

 

 

 

Check the connection of the digital control bus

 

Specify the type of heater manually in the settings

Err.

1 - No connection to the Eberspacher heater

 

Check the type of heater in the settings and connect the digital bus

Err.

2 - No connection to the Eberspacher heater (the heater was started)

 

Check the connection of the digital control bus 

Err.

3 - The Eberspacher heater does not respond to requests

 

Check the heater type in the device settings

Err.

4 - The Eberspacher heater does not respond correctly to requests

 

Check the heater type in the device settings

Err.

5 - Many errors during the operation of the Eberspacher heater

 

Make a digital diagnosis of the heater

Err.

7 - Webasto Thermo Top can not start up

 

Make a digital diagnosis of the heater

Err.

8 - Webasto Thermo Top heater does not respond correctly to requests

 

Check the heater type in the device settings

Err.

9 - Webasto Thermo Top heater does not respond to requests

 

Check the connection of the digital control bus

If errors occur during the operation of the mini-timer, "rN: XX" appears on 
the screen, where N is the error cell number, XX is the error number. To 
switch between cells with error codes, press the "<" or ">" button. To turn 
off the display, press "P".

rN:

64

 

- Short circuit of the digital bus to "+" or "-" during heater operation

 

Check the connection of the digital control bus

rN:

67 - Output OUT is defective

 

It is necessary to transfer the device to the service center

rN:

68 - Exceeding the LINE output current in the analog

ue

 control mode

 

Check the control bus connection

rN:

6

9

 - Exceeding the output current OUT

 

Check the connection and load resistance of the OUT

rN:

6

B

 - Overvoltage at the input of the digital bus

 

It is necessary to transfer the device to the service center

rN:

6

- Short circuit of the digital bus to "-" during data exchange 

rN:

6

- Short circuit of the digital bus to "+" during data exchange 

 

Check the connection of the digital control bus

Note: If there are other error numbers, switch off the appliance and 
contact the service center.