background image

Diagnostics of the heater

The menu is only available when controlling digital types of heaters.
In standby mode (the display is off), press and hold the ">" button and 
additionally press the      button. The display will show "-Hd-", to enter the 
diagnostics mode of the heater, press "P" in addition.
The display will show "FX:YY", where X is the number of the cell with the 
error code, YY is the error code. 
If there are no errors, YY takes the value "-".
To switch between the available cells with error codes, use the "<" and ">" 
buttons. To delete all errors, press and hold the 

    

 button for 3 seconds.

If the Eberspacher heater is diagnosed, then pressing the "P" button will 
move the current fault menu to the saved section from the menu and 
display "EX:YY" with the same parameters.
To turn off the display, press "P" in addition.
Note:

 

description of error codes by the link https://altox.ru/en/docs/

Select heater type

In standby mode (the display is off), press and hold the "<" button and 
additionally press ">". The display will show "H:XY", where X and Y are the 
type of heater and digital protocol (default type is A0).
Set the required type of heater and digital protocol by pressing the "<" and 
">" buttons, following the description:

Automatic/Analog

ue

:

A0 - 

automatic detection of the digital type of heater

A1 - 

heater with analogue signal control

Eberspacher:
Е1 - After Hydronic II

 

E2 - 

F

actory-installed Hydronic II (Toyota, VW)

E3 - 

F

actory-installed Hydronic II (Audi, Land Rover, VW)

E7 - Ventilation

 (

Aftermarket

)

Webasto Thermo Top

:

t1 –

 

Thermo Top C/Z/V/EVO

/

VEVO

t2 –

 

Thermo Top V

/

VEVO

t3 – 

Emulation 

WTT

t4 – 

Emulation

 

Timer

 1533

t5 – 

Emulation

 Telestart (ver.1)

t6 – Emulation Telestart (ver.2)

t

7 – Ventilation (summer mode)

The selected type of heater is stored in memory after pressing "P".
Note:

 

automatic determination of the type Eberspacher and Webasto 

digital heater (mode A0) occurs at the first start.

Display of time, voltage and temperature

The heater is started: To display the remaining operating time of the 
heater, press the "<" or ">" button.
Then, to display the current time, press the "P" button.
The heater is stopped

To display the current time, press the "<" or ">" 

button. In this section of the menu, pressing the "<" or ">" buttons will 
display the seconds value of the current time.
Subsequent pressings of the "P" button switch to the voltage display 
section, and then to the 

car 

parking heater temperature display section.

In the last section, to turn off the display, press the "P" button.
Примечание: The value of the 

car

 parking heater temperature is only 

available on the part of the Eberspacher and Webasto digital heaters. If 
the temperature value is not available, the menu section will be skipped.

Programming the timer 

Three programmable timers are available to the user.
Each of the timers has two modes of operation:
— Single mode for switching on day ahead;
— Weekly mode of daily switching on for 7 days ahead.
Note: After 6 starts, the weekly mode automatically goes into single-turn 
mode.
To view the status of the timer (activated or deactivated), in the standby 
mode (the display is off), you must press the "P" button one, two or three 
times, the display will show the timer number "-1t-"
"-2t-" or "-3t-", respectively.
The status of the timer is determined by the number of points in the right 
corner:
— No points: the timer is deactivated
— One point: the timer is activated in the single-turn mode
— Two points: the timer is activated in a weekly mode
Activate / deactivate the timer and change the timer mode in the current 
menu with the     button.
To change the timer settings, press the "<" or ">" button, the display will 
show the start time of the heater.
Press the "<", ">" and "P" buttons to set the desired start time of the heater, 
then set the operating time of the heater "t:30" from 10 to 99 minutes.
After pressing "P", the settings will be saved and the timer will be 
activated in the single-turn-on mode for the day ahead.
Note: in the timer "-1t-" setting menu, the stored operating time of the 
heater "t:30" is the default start time from the direct-on button     , and 
from the external pulse signal at the INPUT input.

Reviews: