Page 19
SPECIFICATIONS
Maximum Display
5999
Measurement Rate
3 times / second
Temperature
Operating: 0°C ~ 40°C
Storage:
-10°C ~ 50°C
Relative Humidity
<90%
Battery
14500 x 1
Fuse(s)
1A, 1000V,
6x30mm
10A, 1000V,
10x38mm
Size
192 x 89 x 43mm
Weight
~380g (include battery)
Accuracy is specified for 1 year after calibration, at operating temperatures
of 23°C ± 5°C, with relative humidity < 75%. Accuracy specifications take
the form of: ±([% of Reading] + [Counts])
Function
Range
Resolution
Accuracy
±([% of Reading] + [Counts])
Overload
Protection
DC Voltage
600mV
0.1mV
±(0.8%+3)
1000V
6V
0.001V
±(0.5%+5)
60V
0.01V
600V
0.1V
1000V
1V
Remarks: Input Impedance 10M
AC Voltage
600mV
0.1mV
±(1.2%+5)
1000V
6V
0.001V
60V
0.01V
600V
0.1V
±(1.5%+5)
1000V
1V
Remarks:
Input Impedance 10M
Display true RMS value
Frequency Response