Model Q 1074A - OPERATION MANUAL 

 

                                                                                               

 

International Electrical and Relative Symbols 

 

 

AC (Alternating Current) 

 

Important information 

 

DC (Direct Current) 

 

 

Caution risk of electric shock 

 

European Safety Standard 

 

Earth ground 

 

Double insulated 

 

 

Low Battery Indicator 

 

The symbol indicating separate 
collection for electrical and 
electronic equipment. 

 

US Safety Standard. 

 
1.

 

SPECIFICATIONS 

 

1.1 GENERAL SPECIFICATIONS 

           

Display                           

6000 Count LCD display. Max reading is 6000. 

Range control               

Auto range / Manual range control 

Polarity                           

Automatic negative polarity indication. 

Zero adjustment           

Automatic. 

Over range indication    

The "OL" display. 

Low battery                     

The " 

 

 

" is display when the battery voltage is low. 

Auto Power Off             

10 minutes after stopping the switch, or not pressing any operation button, 
the meter automatically enters to power off mode. 

Safety standards   

 

EMC/LVD

. The meter is up to the standards of IEC1010 Pollution 

Degree 2, Overvoltage Category 

.   

Operating environment 

Temperature32 to104°F (0°C to 40°C), humidity< 80% RH. 

Storage environment   

Temperature-4 to140°F (-20°C to 60°C), humidity< 90%RH. 

Power 

One standard 9 volt battery (NEDA 1604

  IEC 6F22 or equivalent) 

Dimension 

98(W)×177(H)×39(D) mm   

Weight   

Approx. 300g (including battery). 

 

1.2 ELECTRICAL SPECIFICATIONS

 

          Accuracy is ± (% of r number in last digit) at 23 ± 5°C, <75% RH. 

       

DC Voltage                                                                           

60mV, 600mV, 6V, 60V                     

±(

0.2%+2

               

600V                                                       

±(

0.3%+2

               

Impedance                                             

10M

Ω

   

Overload protection                           

600V DC/AC RMS. 

 

        AC Voltage   

600mV, 6V, 60V                         

±(

1.0%+3

 

600V                                                       

±(

1.5%+3

 

Impedance                                             

10M

Ω

Frequency response                             

50

1KHz 

Overload protection                             

600V DC/AC RMS. 

 

Summary of Contents for Q 1074A

Page 1: ...hen servicing the meter use only specified replacement parts Use caution when working above 30 V ac rms 42 V peak or 60 V dc Such voltages pose a shock hazard The finger or any part of your body shall...

Page 2: ...tery voltage is low Auto Power Off 10 minutes after stopping the switch or not pressing any operation button the meter automatically enters to power off mode Safety standards EMC LVD The meter is up t...

Page 3: ...5 10A for 15sec each 15min maximum Overload protect Fast fuse 10A 600V Input voltage drop 0 3V Frequency Respond 50Hz 1KHz Note Not to measure a current in a circuit with voltage more than 600V Capaci...

Page 4: ...ts max then return the min range Press RANGE button more than 2 seconds the meter return to auto range This button do not effect on frequency duty cycle capacitance diode continuity test and temperatu...

Page 5: ...current measuring mode 4 For current measurement from 600mA to 10A connect the red test lead to 10A socket Set selector switch to AC DC 10A position and press SELECT button to select DC or ACA measuri...

Page 6: ...rement 5 Read the result from the LCD panel 2 9 Frequency measurement 1 Connect the black test lead to COM socket and red test leads to the V Hz socket 2 Set the selector switch to Hz position 3 Conne...

Page 7: ...sionally to keep it looking new Do not use harsh chemicals cleaning solvents or strong detergents to clean the multimeter 6 Use only fresh batteries of the required size and type Always remove old or...

Page 8: ...and the affection of environment changes will be eliminated 4 2 How to self calibrate a multimeter 1 Rotate the selector switch to position make sure the meter is on Ohm mode 2 Press the Select butto...

Reviews: