- 10 - eBridge200WPM/WPMH

Pole Installation Using Optional Pole Mount Kit PMK1 

(not included)

:

This installation should be made by qualified service personnel. This product contains no serviceable parts. PMK1 is in-
tended for use with Altronix outdoor rated power supplies or accessories housed in WP1, WP2, WP3 and WP4 enclosures. 
Brackets are designed for use with the Wormgear Quick Release Straps (two included).
1.  Thread one (1) wormgear quick release strap through the slots on the back of a mounting bracket (Fig. 17, pg. 10).
2.  Once the desired height of the top Pole Mount bracket is achieved, tighten the straps down by sliding open end
  of the strap through the locking mechanism on the strap, then tighten the screw with
  flat head screwdriver or 5/16” hex socket driver (Fig. 18 pg. 10).

3.  Attach the bottom bracket to the enclosure by inserting bolts through the
  flange of the enclosure and into the bracket, tightening bolts with a
  7/16” hex socket (Fig. 20, pg. 10).
4.  Thread the second wormgear quick release strap through the slots on the
  back of the bottom mounting bracket (Fig. 17, pg. 10).
5.  Mount enclosure onto the top bracket by inserting bolts through
  flange of the enclosure and into the bracket,
  tightening bolts with a 7/16” hex socket (Fig. 19, pg. 10).
6.  Tighten the straps of the bottom bracket down by sliding the open end of
  the strap through the locking mechanism on the strap, then tighten screw
  with flat head screwdriver or 5/16” hex socket driver (Fig. 21/21a, pg. 10).
7.  Clip excess straps.

Fig. 21 - 2” to 8”(50.8mm to 203.2mm) 

Fig. 21a - 5” (127mm) square pole

 

diameter round pole

Fig. 17

Fig. 18

Fig. 19

Fig. 20

Summary of Contents for eBridge200WPM

Page 1: ...d LPS PoE Power Supply See input options table below Power Output 2 ports PoE PoE 30W per port or 1 port Hi PoE 60W Total output power 60W Ethernet Link Distance 500m max with Pace or eBridge100 series PoE receivers to eBridge200WPM or 100m with standard midspan or endspan to eBridge200WPM Connectivity RJ45 auto crossover Wire type 4 pair Cat 5 or better structured cable Device Distance 100m max e...

Page 2: ...5 Mount circuit board in enclosure with hardware 6 To facilitate wire entry utilize weather tight NEMA rated connectors supplied bushings and cable 7 Connect Coax from eBridge1SPR 100SPR 60W eBridge100RM eBridge400RM eBridge800RM or eBridge1600RM 60W receiver to connector marked COAX INPUT Fig 5 pg 3 Connect Cat5 from Pace1PRD 60W Pace1PRM Pace4PRM Pace8PRM Pace16PRM 30W receiver NetWay1D or Midsp...

Page 3: ...TY SPEED ACTIVITY SPR PoE DATA PoE SPR PoE DATA PoE 60W CAT 30W CAT or 60W COAX SW3 60W CAT 30W CAT or 60W COAX CAT 5e 100m CAT 5e 100m CAT 5e 100m Coax 300m Option 1 Option 2 30W Camera Device 30W Camera Device 60W Camera Device eBridge100SPR NetWay1D I T E 43KC www altronix com Input 51 56VDC Class 2 or LPS power supply Blue LED Coax link status SLOC RJ45 LEDs Yellow Speed Green Activity Green L...

Page 4: ...PoE www altronix com IP UTP Receiver Passes PoE PoE Pace1PRD Receiver 1 PORT 1 PORT 2 CAT INPUT COAX INPUT SPEED ACTIVITY SW3 SPEED ACTIVITY SPEED ACTIVITY SPR PoE DATA PoE SPR PoE DATA PoE 60W CAT 30W CAT or 60W COAX SW3 60W CAT 30W CAT or 60W COAX CAT 5e 100m Coax 300m Option 1 15W Camera Device eBridge100RM Midspan or Endspan RJ45 OUT PoE LED PoE LED Coax RJ45 LEDs Yellow Speed Green Activity Y...

Page 5: ...t5e 500m Pace1PRM Z1409 CAT 5e 100m CAT 5e 100m CAT 5e 100m Option 2 15W Camera Device 15W Camera Device 30W Camera Device Midspan or Endspan Option 1 1 PORT 1 PORT 2 CAT INPUT COAX INPUT SPEED ACTIVITY SW3 SPEED ACTIVITY SPEED ACTIVITY SPR PoE DATA PoE SPR PoE DATA PoE 60W CAT 30W CAT or 60W COAX SW3 60W CAT 30W CAT or 60W COAX Cat5e 100m CAT 5e 100m CAT 5e 100m CAT 5e 100m Option 2 15W Camera De...

Page 6: ... button then clicking Settings then clicking Network Connections b Right click the Local Area Connection Click Properties Administrator permission required If you are prompted for an administrator password or confirmation type the password or provide confirmation c Double click Internet Protocol TCP IP menu item d Choose the Obtain an IP address automatically option e Click OK Close all windows Fo...

Page 7: ...specify IPv4 IP address settings click Obtain an IP address automatically and then click OK e To specify IPv6 IP address settings click Obtain an IPv6 address automatically and then click OK Step 2 Connect a laptop or PC to the Ethernet port of the receiver Midspan or Endspan powering your eBridge200WPM WPMH The eBridge200WPM WPMH unit should be powered up at this moment Step 3 Open a browser wind...

Page 8: ...Inbound Port Port number for HTTP WEB communication Host Name Name of the eBridge200WPM WPMH device on the LAN Additional Information 1 If using DHCP all settings will be detected automatically While DHCP is a useful tool for determining the network settings if you set up your eBridge200WPM WPMH in this manner its IP address may change at different times for different reasons particularly after a ...

Page 9: ...rowsing Because of this in order to prevent the average user from hosting a web server most ISPs BLOCK traffic using port 80 from reaching the average site If you only plan to monitor your eBridge200WPM WPMH on a LAN you can use port 80 and don t have to concern yourself with routers However if you desire remote access to your eBridge200WPM WPMH you MUST select functional ports and set up the port...

Page 10: ...ghten the screw with flat head screwdriver or 5 16 hex socket driver Fig 18 pg 10 3 Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the bracket tightening bolts with a 7 16 hex socket Fig 20 pg 10 4 Thread the second wormgear quick release strap through the slots on the back of the bottom mounting bracket Fig 17 pg 10 5 Mount enclosure ont...

Page 11: ...7 159 3mm 10 32 X 0 25 6 4mm 4 Places 4 25 108mm 4 35 110 5mm 6 0 152 4mm 6 75 171 5mm 8 75 222 2mm 8 75 222 2mm 316 Stainless Steel Padlock Latch Attached 0 375 9 5mm Padlock Eye 304 Stainless Steel Piano Hinge 9 32 236 7mm 4 92 125mm 4 0 101 6mm 9 5 241 3mm 0 312 7 9mm TYP 4 Places 0 65 16 5mm Holes 3 Places eBridge200WPMH ...

Page 12: ...9056 website www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIeBridge200WP WPH WPM WPMH A14O MEMBER 1 Place unit at the desired location and secure with mounting screws not included Fig 16a and Fig 16b pg 9 Fig 16a Fig 16b Mechanical Drawing and Dimensions H x W x D approx 9 5 x 7 32 x 4 92 241 3mm x 185 9mm x 125mm Notes ...

Reviews: