background image

More than just power.

TM

Rev. 020317

Two (2) Channel 
365 Day 24 Hr. Timer/Controllers

Models include: 

PT2724 

  -  Timer module

PT2724E 

  -  Timer module in enclosure

Installation Guide

Summary of Contents for PT2724

Page 1: ...More than just power TM Rev 020317 Two 2 Channel 365 Day 24 Hr Timer Controllers Models include PT2724 Timer module PT2724E Timer module in enclosure Installation Guide ...

Page 2: ...oliday dates per channel First man in option Features cont d Standard or Daylight Savings Time settings Automatic compensation for leap year Visual Indicators Alphanumeric LCD display simplifies programming Battery Backup Built in charger for 12VDC sealed lead acid or gel type batteries Max charge current 100mA Optional lithium battery backup maintains clock Order Altronix part LB2032 Mechanical P...

Page 3: ... an existing programmed event Pulse Momentarily energizes the relay for a selectable time period of 1 sec to 15 secs Time is displayed in 24 hr military format Terminal Identification Table Terminal Legend Function Description NO C NC CH A NO C NC CH B Dry Contact outputs used to switch controlled devices When these relays are energized ON the NC and C terminals are open and the NO and C terminals...

Page 4: ...ess ENTER to scroll until flashing cursor appears under DS daylight savings mode in display To change mode depress UP or DWN until ST standard time mode will appear in display Depress ENTER to accept correct selection Note The flashing cursor denotes location of data entry selection to be made If an entry was made in error or requires changing depress SET to backspace make the correct selection an...

Page 5: ...f the event is not programmed the cursor will move to the OFF relay function position If the event is programmed the cursor will move to the position and the programmed information of the event will be displayed At this point depress the UP button to step up through the programmed events When an unprogrammed event is reached the cursor will move to the OFF relay function position At this point ref...

Page 6: ...nel A or B by moving slide switch SW3 to appropriate position Note Channel cannot be changed in the middle of programming events To change channels you must exit programming then change channel switch position then enter program mode again It is now necessary to assign these holiday events specific calendar dates which they are to occur on Depress SET until appears on display Depress ENTER appears...

Page 7: ...ON and Channel B is set to OFF The ON command will override the OFF and both relays will remain ON PT2724 Board Dimensions L x W x H approximate 5 25 x 3 6 x 1 133 4mm x 91 4mm x 25 4mm 5 25 133 4mm 3 6 91 4mm 0 14 3 6mm 0 14 3 6mm 4 9 124 5mm 2 4 61mm Ø0 156 3 9mm PT2724E Enclosure Dimensions H x W x D approximate 8 5 x 7 5 x 3 5 215 9mm x 190 5mm x 88 9mm 1 25 31 75mm 1 25 31 75mm 1 25 31 75mm 1...

Page 8: ...al errors 140 58th Street Brooklyn New York 11220 USA phone 718 567 8181 fax 718 567 9056 website www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIPT2724 F21R MEMBER Customer Event Log Event Relay Day Block Holiday Dates Event Type ...