background image

PT72724

365 Day 24 Hr.
Timer/Controller

Installation/
Programming Guide for

Summary of Contents for PT72724

Page 1: ...PT72724 365 Day 24 Hr Timer Controller Installation Programming Guide for ...

Page 2: ...esired location enclosure Carefully Review Basic Operation pg 2 Terminal Identification Table pg 3 Push Button Layout and Description pg 3 4 Programming Instructions pgs 4 7 2 Connect 12 to 24 Volts AC or DC to terminals marked DC AC when using DC carefully observe polarity 3 Connect 12VDC battery optional to terminals marked BAT 12VDC 4 Insert lithium battery optional not included Order part LB20...

Page 3: ...bserve polarity AC BAT 12VDC standby battery input battery leads provided 12VDC FM When this terminal is connected to DC neg the First Man in feature is enabled Both relays will remain in their present position until this connection is terminated At that time relays will resume normal operation and latest scheduled events will occur PT 2724 SET ENTER UP DWN FM BAT 12VDC DC AC ALTRONIX CORP BKLYN N...

Page 4: ...NTER to SET EVENT Depress ENTER A01 OFF SU 00 00 Note A01 indicates Channel A event 01 When cursor appears you are able to scroll through events Depress ENTER until the flashing cursor appears under OFF relay function position in display Now select type of operation required by scrolling using the UP and DWN push buttons until either ON Relay ON latching mode OFF Relay OFF latching mode PL Relay P...

Page 5: ...hrough Sunday depress WE followed SU 2 Daylight Savings Programming The cursor will appear under DS auto clock adjust daylight savings mode in display To change mode depress UP or DWN once ST clock does not adjust standard time mode will appear in display Depress ENTER to accept correct selection Note Select DS for areas that observe daylight savings or ST for areas that don t observe daylight sav...

Page 6: ...T until ENTER to SET EVENT Depress ENTER A01 ON TU 00 00 Now scroll using UP and DWN push buttons to the event you wish to delete depress ENTER to move flashing cursor under relay option then depress UP and DWN push buttons until DIS is displayed depress ENTER to confirm G Delete All Events This will delete all previously programmed events Depress SET until ENTER to CLR MEM Depress ENTER CLEAR MEM...

Page 7: ...th Street Brooklyn New York 11220 USA 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com Lifetime Warranty Made in U S A MEMBER Event Relay Day Block Holiday Dates Event Type Customer Event Log ...