background image

- 2 - 

ReServWPV

Overview:

ReServWPV Outdoor Video Surveillance UPS units are designed to provide power for 24VAC and/or 12VDC cameras 

during normal or power outage conditions. True sine wave regulated AC outputs and/or regulated DC outputs.

ReServWPV Series Outdoor Video Surveillance UPS Configuration Reference Chart:

Altronix

Model Number

Output/Supply

Current (A)

Ambient

Temperature

Input Rating

PTC Protected 

Power-Limited 

Outputs

24VAC 

Outputs

12VDC 

Outputs

ReServ1WPV

24VAC @ 4A (100VA)

and 12VDC @ 2A

-33º to 30º C

220VAC

50Hz, 2A

16

12

4

24VAC @ 3.5A (85VA)

and 12VDC @ 2A

-33º to 42º C

ReServ2WPV

24VAC @ 4A (100VA)

-33º to 30º C

220VAC

50Hz, 2A

16

16

----

24VAC @ 3.5A (85VA)

-33º to 42º C

ReServ3WPV

12VDC @ 8A

-33º to 42º C

220VAC

50Hz, 2A

16

----

16

Specifications:

Stand-by Specifications:

Stand-by Batteries

ReServ1WPV - 4A (100VA) load at 24VAC and 2A load at 12VDC max.

ReServ2WPV - 4A (100VA) max. load at 24VAC

ReServ3WPV - 8A (100VA) max. load at 12VDC

Two (2) 12VDC/7AH

45 minutes

Two (2) 12VDC/12AH

90 minutes

Installation Instructions:

This installation should be made by qualified service personnel and should conform to all local codes and in accordance 

with the National Electrical Code. This product contains no serviceable parts.

1.  Remove back plate inside the enclosure by removing the four (4) mounting screws.

2.  Mark and drill desired knockouts on the enclosure to facilitate wiring (Fig. 1, pg. 3).

 

Note: It is required to use UL Listed outdoor rated conduit hubs with a minimum outdoor rating of 4X.

3.  Secure back plate inside enclosure with the four (4) mounting screws.

4.  Mark and drill holes that line up with the top and bottom holes of the enclosure flange Mount unit in the desired

 

location with the appropriate fasteners (Pgs. 7 and 8). Secure enclosure to earth ground. 

 

Note: This product needs to be secured to the building/pole before operation.

5.  Connect AC power mains to the terminals marked [L] and [N] (Figs. 2-3, pg. 5-6).

 

Use 18 AWG or larger for all power connections (Battery, output) (Figs. 2-3, pg. 5-6).

 

Use 18 AWG to 22 AWG for power limited circuits (AC Fail/Low Battery reporting) (Figs. 2-3, pg. 5-6).

 

Note: A readily accessible disconnect device shall be incorporated in the building installation wiring.

6.  The LEDs on the power supply board will illuminate when AC power is present.

7.  Measure output voltage before connecting cameras/devices to outputs. This helps avoiding potential damage.

8.  ReServ3WPV only - Adjust voltage for every two (2) outputs using the corresponding trimpot(s) on the board prior

 

to connecting devices.

Output:

• PTC protected power-limited outputs are rated @ 1A.

Battery Backup:

•  Built-in charger for sealed lead acid or gel type batteries. 

•  Automatic switchover to stand-by battery when AC fails.

Supervision:

• AC fail supervision (form “C” contacts). 

• Low battery supervision (form “C” contacts). 

Visual and Audio Indicators:

• AC/DC power LED indicators.

• Individual power output LED indicators.

• Low voltage input and Shutdown LED indicators.

• Audio AC Fail and Battery Fail indicator.

Additional Features:

• True sine wave regulated AC outputs (ReServ1WPV and 

  ReServ2WPV). Regulated DC outputs (ReServ1WPV and 

 ReServ3WPV).

• Unit maintains camera synchronization. 

• Ease of installation saves time and eliminates costly labor.

Enclosure Dimensions:

• NEMA4 / IP66 Rated enclosure.

•  Accommodates up to two (2) 12VDC/7AH batteries or  

  two (2) 12VDC/12AH batteries.

17.375” x 12” x 6.5” (441.3mm x 304.8mm x 165.1mm)

Summary of Contents for ReServ1WPV

Page 1: ...utputs 4A total supply current 24VAC and 2A total supply current 12VDC PTC protected power limited outputs ReServ2WPV Sixteen 16 true sine wave regulated 24VAC outputs 4A total supply current PTC protected power limited outputs ReServ3WPV Sixteen 16 regulated 12VDC outputs 8A total supply current PTC protected power limited outputs More than just power ...

Page 2: ... with the top and bottom holes of the enclosure flange Mount unit in the desired location with the appropriate fasteners Pgs 7 and 8 Secure enclosure to earth ground Note This product needs to be secured to the building pole before operation 5 Connect AC power mains to the terminals marked L and N Figs 2 3 pg 5 6 Use 18 AWG or larger for all power connections Battery output Figs 2 3 pg 5 6 Use 18 ...

Page 3: ...y outputs 12 The power LEDs on the unit for Outputs 1 16 will illuminate when AC power is present Figs 2 3 pg 5 6 Note If any of the power LEDs are not illuminated the cause may be due to the following a AC mains and battery fail b One 1 or more power output PTCs are tripped due to a short circuit or overload condition c Unit damaged defective To reset the PTC 1 Disconnect corresponding camera dev...

Page 4: ...esent terminals marked NO and C are open NC and C are closed When loss of AC occurs terminals marked NO and C are closed NC and C are open BAT FAIL NO C NC Form C dry contacts used to signal low battery voltage or loss of battery voltage Under normal conditions terminals marked NO and C are open NC and C are closed During a trouble condition terminals marked NO and C are closed and NC and C are op...

Page 5: ...A power mains non power limited power limited For outputs configuration refer to Step 9 Pg 3 of Installation Instructions Note Two 2 12VDC rechargeable batteries connected in series required Supervised Non power limited CAUTION Risk of explosion if battery is replaced by an incorrect type Dispose of used batteires according to the instructions 12VDC Rechargeable Battery order separately ...

Page 6: ...k of explosion if battery is replaced by an incorrect type Dispose of used batteires according to the instructions 12VDC Rechargeable Battery order separately P N 1 OUT 2 1 2V adjust P N 3 OUT 4 3 4V adjust P N 5 OUT 6 5 6V adjust P N 7 OUT 8 7 8V adjust P N 9 OUT 10 9 10V adjust P N 11 OUT 12 11 12V adjust P N 13 OUT 14 13 14V adjust P N 15 OUT 16 15 16V adjust 9 10 11 12 13 14 15 16 1 2 3 4 5 6 ...

Page 7: ...the strap through the locking mechanism on the strap then tighten the screw with flat head screwdriver or 5 16 hex socket driver Fig 6 pg 7 3 Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the bracket tightening bolts with a 7 16 hex socket Fig 8 pg 7 4 Thread the second wormgear quick release strap through the slots on the back of the bo...

Page 8: ...718 567 8181 fax 718 567 9056 website www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIReServWPV Rev 021412 F16P 16 406mm 6 5 165 1mm 17 375 441 3mm 10 254mm 16 75 425 45mm 12 304 8mm 10 875 276 2mm 14 875 377 83mm 0 3125 7 9375mm 0 5 12 7mm 4 5 114 3mm Enclosure Dimensions H x W x D approximate 17 375 x 12 x 6 5 441 3mm x 304 8mm x 165 1mm MEMBER ...

Reviews: