background image

- 4 - 

ReServWPV

LED Diagnostics:

Power Supply Board

Red (DC)

Green (AC1)

Power Supply Status

ON

ON

Normal operating condition.

ON

OFF

Loss of AC. Stand-by battery supplying power.

OFF

ON

No DC output.

OFF

OFF

Loss of AC. Discharged or no stand-by battery. No Dc output.

ReServ Board

LED

LED State

Unit Status

Output LEDs

ON

------

Normal operating condition.

------

OFF Loss of 24VACand/or 12VDC output power.

Low Battery

ON

------

Stand-by batteries are low.

------

OFF Normal operating condition.

Shutdown

ON

------

Loss of 24VACand/or 12VDC output power. Discharged stand-by battery.

------

OFF Normal operating condition.

Audio Signal Diagnostics:

ReServ Unit

Audio Signal

Unit Status

Single Periodic Beep

AC Fail.

Double Periodic Beep Low Battery or No Battery.

Terminal Identification:

Power Supply Board

Terminal Legend Function/Description
L, G, N

Connect 220VAC 50Hz to these terminals: L to hot, N to neutral, G to ground.

--  DC +

24VDC non power-limited output. 

AC FAIL 

NO, C, NC

Form “C” dry contacts used to instantaneously signal the loss AC to local annunciation devices, 

with AC present terminals marked NO and C are open, NC and C are closed. When loss of AC

occurs, terminals marked NO and C are closed, NC and C are open.

BAT FAIL 

NO, C, NC

Form “C” dry contacts used to signal low battery voltage or loss of battery voltage. Under normal 

conditions terminals marked NO and C are open, NC and C are closed. During a trouble condition 

terminals marked NO and C are closed, and NC and C are open.

--  BAT +

Stand-by battery connections. Maximum charge current 0.7A.

ReServ Board

Terminal Legend

Function/Description

Input  ---  24VDC +

24VDC input from power supply board.

N, P 1-16

24VAC and/or 12VDC outputs. 

The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the

presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient

magnitude to constitute an electric shock.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important 

operating and maintenance (servicing) instructions in the literature accompanying the appliance.

CAUTION: To reduce the risk of electric shock do not open enclosure.

There are no user serviceable parts inside. Refer servicing to qualified

service personnel. 

Summary of Contents for ReServ1WPV

Page 1: ...utputs 4A total supply current 24VAC and 2A total supply current 12VDC PTC protected power limited outputs ReServ2WPV Sixteen 16 true sine wave regulated 24VAC outputs 4A total supply current PTC protected power limited outputs ReServ3WPV Sixteen 16 regulated 12VDC outputs 8A total supply current PTC protected power limited outputs More than just power ...

Page 2: ... with the top and bottom holes of the enclosure flange Mount unit in the desired location with the appropriate fasteners Pgs 7 and 8 Secure enclosure to earth ground Note This product needs to be secured to the building pole before operation 5 Connect AC power mains to the terminals marked L and N Figs 2 3 pg 5 6 Use 18 AWG or larger for all power connections Battery output Figs 2 3 pg 5 6 Use 18 ...

Page 3: ...y outputs 12 The power LEDs on the unit for Outputs 1 16 will illuminate when AC power is present Figs 2 3 pg 5 6 Note If any of the power LEDs are not illuminated the cause may be due to the following a AC mains and battery fail b One 1 or more power output PTCs are tripped due to a short circuit or overload condition c Unit damaged defective To reset the PTC 1 Disconnect corresponding camera dev...

Page 4: ...esent terminals marked NO and C are open NC and C are closed When loss of AC occurs terminals marked NO and C are closed NC and C are open BAT FAIL NO C NC Form C dry contacts used to signal low battery voltage or loss of battery voltage Under normal conditions terminals marked NO and C are open NC and C are closed During a trouble condition terminals marked NO and C are closed and NC and C are op...

Page 5: ...A power mains non power limited power limited For outputs configuration refer to Step 9 Pg 3 of Installation Instructions Note Two 2 12VDC rechargeable batteries connected in series required Supervised Non power limited CAUTION Risk of explosion if battery is replaced by an incorrect type Dispose of used batteires according to the instructions 12VDC Rechargeable Battery order separately ...

Page 6: ...k of explosion if battery is replaced by an incorrect type Dispose of used batteires according to the instructions 12VDC Rechargeable Battery order separately P N 1 OUT 2 1 2V adjust P N 3 OUT 4 3 4V adjust P N 5 OUT 6 5 6V adjust P N 7 OUT 8 7 8V adjust P N 9 OUT 10 9 10V adjust P N 11 OUT 12 11 12V adjust P N 13 OUT 14 13 14V adjust P N 15 OUT 16 15 16V adjust 9 10 11 12 13 14 15 16 1 2 3 4 5 6 ...

Page 7: ...the strap through the locking mechanism on the strap then tighten the screw with flat head screwdriver or 5 16 hex socket driver Fig 6 pg 7 3 Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the bracket tightening bolts with a 7 16 hex socket Fig 8 pg 7 4 Thread the second wormgear quick release strap through the slots on the back of the bo...

Page 8: ...718 567 8181 fax 718 567 9056 website www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIReServWPV Rev 021412 F16P 16 406mm 6 5 165 1mm 17 375 441 3mm 10 254mm 16 75 425 45mm 12 304 8mm 10 875 276 2mm 14 875 377 83mm 0 3125 7 9375mm 0 5 12 7mm 4 5 114 3mm Enclosure Dimensions H x W x D approximate 17 375 x 12 x 6 5 441 3mm x 304 8mm x 165 1mm MEMBER ...

Reviews: